High variability in strain estimation errors when using a commercial ultrasound speckle tracking algorithm on tendon tissue
KTH, School of Technology and Health (STH), Medical Engineering.ORCID iD: 0000-0001-9419-910X
KTH, School of Technology and Health (STH), Medical Engineering.ORCID iD: 0000-0002-5795-9867
KTH, School of Technology and Health (STH), Medical Engineering.ORCID iD: 0000-0003-1264-1254
Show others and affiliations
2016 (English)In: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 57, no 10, p. 1223-1229Article in journal (Refereed) Published
Abstract [en]

Background: Ultrasound speckle tracking offers a non-invasive way of studying strain in the free Achilles tendon where no anatomical landmarks are available for tracking. This provides new possibilities for studying injury mechanisms during sport activity and the effects of shoes, orthotic devices, and rehabilitation protocols on tendon biomechanics. Purpose: To investigate the feasibility of using a commercial ultrasound speckle tracking algorithm for assessing strain in tendon tissue. Material and Methods: A polyvinyl alcohol (PVA) phantom, three porcine tendons, and a human Achilles tendon were mounted in a materials testing machine and loaded to 4% peak strain. Ultrasound long-axis cine-loops of the samples were recorded. Speckle tracking analysis of axial strain was performed using a commercial speckle tracking software. Estimated strain was then compared to reference strain known from the materials testing machine. Two frame rates and two region of interest (ROI) sizes were evaluated. Results: Best agreement between estimated strain and reference strain was found in the PVA phantom (absolute error in peak strain: 0.21 +/- 0.08%). The absolute error in peak strain varied between 0.72 +/- 0.65% and 10.64 +/- 3.40% in the different tendon samples. Strain determined with a frame rate of 39.4Hz had lower errors than 78.6Hz as was the case with a 22mm compared to an 11mm ROI. Conclusion: Errors in peak strain estimation showed high variability between tendon samples and were large in relation to strain levels previously described in the Achilles tendon.

Place, publisher, year, edition, pages
Sage Publications, 2016. Vol. 57, no 10, p. 1223-1229
Keywords [en]
Speckle tracking, strain, Achilles tendon, ultrasound
National Category
Medical Instrumentation Medical Laboratory Technologies
Identifiers
URN: urn:nbn:se:kth:diva-193792DOI: 10.1177/0284185115626471ISI: 000382967500013PubMedID: 26787677Scopus ID: 2-s2.0-84987786849OAI: oai:DiVA.org:kth-193792DiVA, id: diva2:1039535
Funder
Stockholm County CouncilSwedish National Centre for Research in Sports
Note

QC 20161024

Available from: 2016-10-24 Created: 2016-10-11 Last updated: 2025-02-10Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textPubMedScopus

Authority records

Mårtensson, MattiasLarsson, MatildaJanerot-Sjöberg, Birgitta

Search in DiVA

By author/editor
Mårtensson, MattiasLarsson, MatildaJanerot-Sjöberg, Birgitta
By organisation
Medical Engineering
In the same journal
Acta Radiologica
Medical InstrumentationMedical Laboratory Technologies

Search outside of DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric score

doi
pubmed
urn-nbn
Total: 591 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf