Interfacing solutions for power hardware-in-the- loop simulations of distribution feeders for testing monitoring and control applications
TU/Eindhoven.
TU/Eindhoven.
TU/Eindhoven.
KTH, School of Electrical Engineering (EES), Industrial Information and Control Systems. KTH, School of Electrical Engineering (EES), Electric Power and Energy Systems.
2017 (English)In: IET Generation, Transmission & Distribution, ISSN 1751-8687, E-ISSN 1751-8695Article in journal (Refereed) Published
Abstract [en]

The need for advanced monitoring and control applications (MCAs) in future distribution networks calls for highly accurate and fully integrated simulation solutions for the purpose of performance assessment of these MCAs. Offline simulation using models of the power system, measurement equipment, local controllers and the information and communication infrastructure do not always resemble reality accurate enough. Therefore, power hardware-in-the-loop (PHIL) simulations are considered a cost-effective approach to overcome these challenges. This study presents the design of a PHIL-interface that allows to integrate a physical low-voltage feeder within a larger real-time simulated distribution network. Using the combination of the physical network and the larger simulated network, MCAs can be tested for scalability as well as accuracy. A data acquisition and processing system is presented that acquires all the true system states of both the physical feeder and the real-time simulated network, such that the MCAs can be verified in real-time. The functioning of the PHIL-interface is validated using practical results and illustrated using a test case for the performance assessment of a branch current state estimation algorithm.

Place, publisher, year, edition, pages
IET Digital Library, 2017.
National Category
Engineering and Technology
Research subject
Electrical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-208197DOI: 10.1049/iet-gtd.2016.1583ISI: 000411402800015Scopus ID: 2-s2.0-85029744352OAI: oai:DiVA.org:kth-208197DiVA, id: diva2:1104870
Note

QC 20170613

Available from: 2017-06-02 Created: 2017-06-02 Last updated: 2025-03-26Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Nordström, Lars

Search in DiVA

By author/editor
Nordström, Lars
By organisation
Industrial Information and Control SystemsElectric Power and Energy Systems
In the same journal
IET Generation, Transmission & Distribution
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 416 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf