kth.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Application-oriented input design for room occupancy estimation algorithms
KTH, School of Electrical Engineering (EES), Centres, ACCESS Linnaeus Centre. KTH, School of Electrical Engineering (EES), Automatic Control.ORCID iD: 0000-0003-0283-5717
KTH, School of Electrical Engineering (EES), Automatic Control. KTH, School of Electrical Engineering (EES), Centres, ACCESS Linnaeus Centre.
KTH, School of Electrical Engineering (EES), Centres, ACCESS Linnaeus Centre. KTH, School of Electrical Engineering (EES), Automatic Control.ORCID iD: 0000-0002-1927-1690
Show others and affiliations
2017 (English)In: 2017 IEEE 56TH ANNUAL CONFERENCE ON DECISION AND CONTROL (CDC), IEEE , 2017Conference paper, Published paper (Refereed)
Abstract [en]

We consider the problem of occupancy estimation in buildings using available environmental information. In particular, we study the problem of how to collect data that is informative enough for occupancy estimation purposes. We thus propose an application-oriented input design approach for designing the ventilation signal to be used while collecting the system identification datasets. The main goal of the method is to guarantee a certain accuracy in the estimated occupancy levels while minimizing the experimental time and effort. To take into account potential limitations on the actuation signals we moreover formulate the problem as a recursive nonlinear and nonconvex optimization problem, solved then using exhaustive search methods. We finally corroborate the theoretical findings with some numerical examples, which results show that computing ventilation signals using experiment design concepts leads to occupancy estimator performing 4 times better in terms of Mean Square Error (MSE).

Place, publisher, year, edition, pages
IEEE , 2017.
Series
IEEE Conference on Decision and Control, ISSN 0743-1546
Keywords [en]
Occupancy estimation, CO2 dynamics, application-oriented input design, minimum-time input design
National Category
Control Engineering
Identifiers
URN: urn:nbn:se:kth:diva-223848DOI: 10.1109/CDC.2017.8264159ISI: 000424696903050Scopus ID: 2-s2.0-85046132323ISBN: 978-1-5090-2873-3 (print)OAI: oai:DiVA.org:kth-223848DiVA, id: diva2:1187947
Conference
IEEE 56th Annual Conference on Decision and Control (CDC), DEC 12-15, 2017, Melbourne, AUSTRALIA
Funder
Swedish Research Council
Note

QC 20180306

Available from: 2018-03-06 Created: 2018-03-06 Last updated: 2022-06-26Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Ebadat, AfroozWahlberg, BoJohansson, Karl H.

Search in DiVA

By author/editor
Ebadat, AfroozVaragnolo, D.Wahlberg, BoJohansson, Karl H.
By organisation
ACCESS Linnaeus CentreAutomatic Control
Control Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 103 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf