kth.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Coherence in Synchronizing Power Networks with Distributed Integral Control
KTH, School of Industrial Engineering and Management (ITM). KTH, School of Electrical Engineering (EES), Centres, ACCESS Linnaeus Centre.
KTH, School of Industrial Engineering and Management (ITM). KTH, School of Electrical Engineering (EES), Centres, ACCESS Linnaeus Centre.ORCID iD: 0000-0001-8975-1801
KTH, School of Industrial Engineering and Management (ITM). KTH, School of Electrical Engineering (EES), Centres, ACCESS Linnaeus Centre.ORCID iD: 0000-0003-1835-2963
KTH, School of Industrial Engineering and Management (ITM). KTH, School of Electrical Engineering (EES), Centres, ACCESS Linnaeus Centre.ORCID iD: 0000-0001-9940-5929
2017 (English)In: 2017 IEEE 56th Annual Conference on Decision and Control, CDC 2017, IEEE , 2017, p. 6683-6688Conference paper, Published paper (Refereed)
Abstract [en]

We consider frequency control of synchronous generator networks and study transient performance under both primary and secondary frequency control. We model random step changes in power loads and evaluate performance in terms of expected deviations from a synchronous frequency over the synchronization transient; what can be thought of as lack of frequency coherence. We compare a standard droop control strategy to two secondary proportional integral (PI) controllers: centralized averaging PI control (CAPI) and distributed averaging PI control (DAPI). We show that the performance of a power system with DAPI control is always superior to that of a CAPI controlled system, which in turn has the same transient performance as standard droop control. Furthermore, for a large class of network graphs, performance scales unfavorably with network size with CAPI and droop control, which is not the case with DAPI control. We discuss optimal tuning of the DAPI controller and describe how internodal alignment of the integral states affects performance. Our results are demonstrated through simulations of the Nordic power grid.

Place, publisher, year, edition, pages
IEEE , 2017. p. 6683-6688
Series
IEEE Conference on Decision and Control, ISSN 0743-1546
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-223842DOI: 10.1109/CDC.2017.8264613ISI: 000424696906009Scopus ID: 2-s2.0-85046157863ISBN: 978-1-5090-2873-3 (print)OAI: oai:DiVA.org:kth-223842DiVA, id: diva2:1188006
Conference
IEEE 56th Annual Conference on Decision and Control (CDC), DEC 12-15, 2017, Melbourne, Australia
Funder
Knut and Alice Wallenberg FoundationSwedish Foundation for Strategic ResearchSwedish Research Council, 2014-6282; 2013-5523
Note

QC 20180306

Available from: 2018-03-06 Created: 2018-03-06 Last updated: 2022-11-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Andreasson, MartinSjödin, EmmaSandberg, HenrikJohansson, Karl H.

Search in DiVA

By author/editor
Andreasson, MartinSjödin, EmmaSandberg, HenrikJohansson, Karl H.
By organisation
School of Industrial Engineering and Management (ITM)ACCESS Linnaeus Centre
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 354 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf