The Effects of Different Earth Pressure Coefficient at Rest in Triaxial Shear Tests on Clay
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Soil and Rock Mechanics.
2017 (English)Independent thesis Advanced level (degree of Master (Two Years)), 10 credits / 15 HE creditsStudent thesis
Abstract [en]

Triaxial shear test is the most accurate test for deciding the undrained shear strength of clay. In every test the ratio between the horizontal and vertical stresses, the coefficient of earth pressure at rest (K0′), has to be decided. It’s widely believed that the choice of this parameter will influence the results, but it’s not known to what extent.

In this thesis 20 consolidated undrained active triaxial shear tests on clay has been con- ducted with a K0′ at 0.6 and 0.8. The clay was collected with a 54 mm piston sampler at the Norwegian Geo-Test Site in Trondheim, Norway, on depth of 3.0 to 7.8 meters. Besides the triaxial testing, index tests and oedometer tests was conducted on every cylinder to do a gen- eral classification of the clay. The clay has a sensitivity of 9-20, a water content of 35-51 %, a plasticity index of 27-65 % and an over consolidation ratio of 2.6-6.8.

The consolidation phase of the triaxial test was conducted in five loading steps with a rest time in-between to monitor the amount of pore water expelled at each stress level. The loading steps was 50 %, 75 % and 100 % of maximum cell pressure and thereafter at 50 % and 100 % of the maximum deviator stress. The shear phase was done at a speed of 1.5 % per hour to a total of 10 % axial strain.

It is not possible to reach an unambiguous conclusion from the results, but the maximum shear strength of tests with a K0′ at 0.8 is 17 % higher, while the total amount of pore water extortion is equal between the two values. The amount of creep in the latest steps is on the other hand smaller for a K0′ at 0.8. This indicates that the soil is handling the stress level better than with a K0′ at 0.6.

Place, publisher, year, edition, pages
2017. , p. 68
Series
TRITA-ABE-MBT ; 1812
Keywords [en]
Clay, Triaxial Shear Tests, Earth Pressure Coefficient
National Category
Geotechnical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-228544OAI: oai:DiVA.org:kth-228544DiVA, id: diva2:1210217
External cooperation
Norwegian University of Science and Technology; Multiconsult Norge AS
Subject / course
Soil and Rock Mechanics
Educational program
Master of Science in Engineering - Urban Management
Supervisors
Examiners
Available from: 2018-05-28 Created: 2018-05-27 Last updated: 2018-05-28Bibliographically approved

Open Access in DiVA

fulltext(10383 kB)54 downloads
File information
File name FULLTEXT01.pdfFile size 10383 kBChecksum SHA-512
bc0e49aa9c9131a2e59aa806c715dc892315499c98335a3eb8388538b4dbf74fb2138e93041b29f4b214192ff4c76adc37a5386af18be83b9873335d2a9373be
Type fulltextMimetype application/pdf

By organisation
Soil and Rock Mechanics
Geotechnical Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 54 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 96 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf