kth.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Effects of Dynamic Line Rating on the Durability and Mechanical Strength of Aluminum Cable Steel Reinforced (ACSR) Conductors
KTH, School of Electrical Engineering and Computer Science (EECS), Electrical Engineering, Electromagnetic Engineering. (QED Asset Management group)
KTH, School of Electrical Engineering and Computer Science (EECS), Electrical Engineering, Electromagnetic Engineering. (QED Asset Management group)ORCID iD: 0000-0002-4065-715X
KTH, School of Electrical Engineering and Computer Science (EECS), Electrical Engineering, Electromagnetic Engineering. (QED Asset Management group)ORCID iD: 0000-0002-2964-7233
2019 (English)In: Innovative Solutions for Energy Transitions, Elsevier, 2019, Vol. 158, p. 3164-3169Conference paper, Published paper (Refereed)
Abstract [en]

Dynamic Line Rating (DLR) is an emerging technology, which provides better utilization of power lines, by using real-time information on the weather parameters to dynamically adjust line rating limits. The power line capacity is highly dependent on its heat balance. The heat balance is influenced by external factors such as wind speed, ambient temperature, humidity, solar radiation and load. DLR analyses have shown high economical and reliability benefits from power system perspective. However, the mechanical stress on the conductor due to differences in thermal expansion characteristics of Aluminum and Steel materials could lead to faster ageing and mechanical damages. The study aims to provide better understanding of the risks associated with DLR application, which can affect conductor's mechanical lifetime. The reliability analysis of transient expansion and shrinkage of the material has identified the risks to the conductor mechanical strength that are associated with dynamic heating and cooling.

Place, publisher, year, edition, pages
Elsevier, 2019. Vol. 158, p. 3164-3169
Series
Energy Procedia, ISSN 1876-6102 ; 158
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-239530DOI: 10.1016/j.egypro.2019.01.1019ISI: 000471031703082Scopus ID: 2-s2.0-85063912210OAI: oai:DiVA.org:kth-239530DiVA, id: diva2:1265518
Conference
10th International Conference on Applied Energy, ICAE 2018; Hong Kong; China; 22 August 2018 through 25 August 2018
Projects
Dynamic rating with applications to renewable energy
Funder
SweGRIDS - Swedish Centre for Smart Grids and Energy Storage, FPS18StandUp for WindSwedish Energy Agency
Note

QC 20181126

Available from: 2018-11-23 Created: 2018-11-23 Last updated: 2022-06-26Bibliographically approved
In thesis
1. Dynamic Rating with Applications to Renewable Energy
Open this publication in new window or tab >>Dynamic Rating with Applications to Renewable Energy
2020 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Dynamic rating (DR) of power components is a method for assessing real-time capacity of large scale power transmission and distribution devices (commonly: transmission lines, power transformers, underground cables) and using this knowledge for adjusting loading limits of these components. 

Dynamic rating of power lines or dynamic line rating (DLR) is a pioneering technology in the area of dynamic rating. Heat balance of an overhead conductor is a defining factor when designing capacity limits for power lines. The maximum ampacity of the power line depends on the factors, such as ambient temperature, wind speed, wind direction, solar radiation, humidity, location, height above the sea level and conductor dimensions and material properties. 

Dynamic transformer rating (DTR) is a new emerging technology with high interest from industry and academia. Similarly to DLR, the dynamic rating of transformers relies on a thermal assessment of the device by locating the hottest spot in the transformer windings. The hot-spot temperature is the limiting factor for determining the maximum allowable ampacity. By shifting from the power-constrained the loading limits to the temperature-constrained, it is possible to achieve much better utilization of power transformer.

Recently, DLR became a recognizable concept in the power systems research community; DTR is also slowly gaining its popularity among researchers. At the same time, the industry begins to recognize DR benefits and invest in dynamic rating technologies. However, there exist many unanswered questions to the technology's reliability, applicability and safe operation. One of the central questions is: how to integrate dynamic rating into short term and long term planning decisions?

he results of the work presented in this thesis show that dynamic rating has high potential to improve power system performance and reduce the costs for power dispatch and increase the share of the renewable energy in the electricity mix. Together with that dynamic rating can help to make renewable energy more accessible by decrease the investment needed for supplying the electricity demand and providing cheaper and faster grid connection.

Abstract [sv]

Dynamisk rating (DR) av elkraftkomponenter syftar till tekniker för att uppskatta kapaciteten hos komponenter för storskalig överföring av elkraft (vanligtvis: kraftledningar, transformatorer, underjordiska kablar) i realtid och använda denna information för att justera belastningsgränserna för dessa. 

Dynamisk rating av kraftledningar (DLR) är en nydanande teknik inom detta område. Värmebalansen för en kraftledning är en viktig faktor för att bestämma dess överföringskapacitet. En kraftlednings maximala strömledningsförmåga beror därför på faktorer så som temperatur, vindhastighet, vindriktning, solstrålning, fuktighet, geografiskt läge, höjd över havet och ledarens dimensioner och materialegenskaper.

Dynamisk rating av transformatorer (DTR) är en ny teknik med stort intresse från industri och akademi. Liknande som för DLR använder sig DTR av en uppskattning av den hot-spot temperaturen, hos komponenten genom att hitta den varmaste punkten i transformatorlindningarna. Hot-spot temperaturen är den begränsande faktorn för att avgöra transformatorns överföringskapacitet. Genom att låta den maximalt tillåtna belastningen bero på temperaturen istället för effekten kan utnyttjandet av transformatorn förbättras väsentligt. 

Nyligen har DLR blivit ett erkänt koncept inom forskningen för elkraft och DTR har också börjat bli populärt bland forskare. Samtidigt har industrin börjat se fördelarna av DR och investera i dessa tekniker. Det finns dock fortfarande många frågor kring teknikern som rör tillförlitlighet, applicerbarhet och säkerhet. En av de viktigaste frågorna är hur man bäst kan integrera dynamisk rating i kort- och långtidsplaneringen av elkraftsystem.

Resultaten av arbetet som presenteras i denna avhandling visar att dynamisk rating har en stor potential att minska kostnaderna för driften av elnätet och tillåta integrering av mer förnybara energikällor. Dessutom kan dynamisk rating göra förnybar energi mer tillgänglig genom att minska de investeringar som krävs för att tillgodose efterfrågan på elektricitet och möjliggöra snabbare och billigare anslutning till elnätet.

Place, publisher, year, edition, pages
Stockholm,: KTH Royal Institute of Technology, 2020. p. 84
Series
TRITA-EECS-AVL ; 2020:3
Keywords
dynamic rating, dynamic line rating, dynamic transformer rating, power transformers, power system optimization, wind farm planning
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Electrical Engineering
Identifiers
urn:nbn:se:kth:diva-266363 (URN)978-91-7873-390-3 (ISBN)
Public defence
2020-01-31, Kollegiesalen, Brinellvägen 8, Stockholm, 14:00 (English)
Opponent
Supervisors
Funder
Swedish Energy AgencySweGRIDS - Swedish Centre for Smart Grids and Energy Storage, FPS18StandUp for Wind
Note

QC 20200109

Available from: 2020-01-09 Created: 2020-01-09 Last updated: 2024-01-12Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopusconference

Authority records

Naim, WadihMorozovska, KaterynaHilber, Patrik

Search in DiVA

By author/editor
Naim, WadihMorozovska, KaterynaHilber, Patrik
By organisation
Electromagnetic Engineering
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 248 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf