Energy Performance of Ground-source Heat Pump and Photovoltaic/thermal (PV/T) in Retrofitted and New Buildings: Two Case Studies Using Simulation and On-site Measurements
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Applied Thermodynamics and Refrigeration.ORCID iD: 0000-0001-8614-5806
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Applied Thermodynamics and Refrigeration.ORCID iD: 0000-0001-7354-6643
2020 (English)Conference paper, Published paper (Refereed)
Abstract [en]

This paper aims to contribute by presenting calculated and measured electricity usage in two single-family case studies during the heating season of 2019-2020 located in Stockholm, Sweden. The electricity usage included consumption by heat pumps’ compressor to cover space heating and domestic hot water, auxiliary energy for fans and pumps, and ventilation system. The first case study was built in 1936 with an oil burner, which was renovated to a ground-source heat pump (GSHP) in 2015, and the second case study was a new building built in 2013 with a GSHP. The application of photovoltaic/thermal (PVT) systems in combination with GSHP was theoretically investigated for both case studies. Buildings were modelled using the energy simulation tool IDA Indoor Climate and Energy (ICE), and the model was validated against the measured electrical energy usage. PVT was designed to balance the maximum heat production with domestic hot water consumption during the summer months. Simulation results revealed that combining GSHP with 5 m2 grid-connected PVT gave 21% and 22% energy savings in case study 1 and case study 2, respectively. Employing a battery storage to store extra electricity production by PVT increased the energy savings to 24 % and 32 % for case study 1 and case study 2, respectively. Moreover, in both cases approximately half of the total annual domestic hot water need was prepared by 5 m2 PVT.

Place, publisher, year, edition, pages
2020.
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:kth:diva-279433OAI: oai:DiVA.org:kth-279433DiVA, id: diva2:1459759
Conference
BuildSim Nordic 2020 Conference
Note

QC 20200821

Available from: 2020-08-20 Created: 2020-08-20 Last updated: 2022-06-26Bibliographically approved

Open Access in DiVA

fulltext(252 kB)301 downloads
File information
File name FULLTEXT01.pdfFile size 252 kBChecksum SHA-512
ef8a0cb0f451172e9b826a21f0f669753d0f0d4d4c3149b8451125942a73dd681b766a06d997894563716493b919db70235fc8f5e739d67d067958b650990184
Type fulltextMimetype application/pdf

Authority records

Hesaraki, ArefehMadani Larijani, Hatef

Search in DiVA

By author/editor
Hesaraki, ArefehMadani Larijani, Hatef
By organisation
Applied Thermodynamics and Refrigeration
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 304 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 426 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf