Frost prediction in heat exchangers: The influence of relative humidity and outdoor temperature on frost formation in plate heat exchangers
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Concrete Structures.
2022 (English)Independent thesis Advanced level (degree of Master (Two Years)), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

Frost in Mechanical Ventilation with Heat Recovery (MVHR) often occurs when indoor air is humid and outdoor air is cold. Warm and humid air from the rooms condensates or sublimates when it becomes cold enough, causing frost to grow in the heat exchanger channels. These layers of frost introduce a pressure loss over the heat exchanger and act as an insulating layer, lowering the heat recovery rate of the heat exchanger. It can also buckle the heat exchanger plates and cause long-term damage. The report outlines a method to calculate the frost limit curve for residential parallel and counter flow heat exchangers. A real heat exchanger model from company Swegon is used to provide an example of the method being used. The method involves a well-known Number of Transfer Units (NTU) equation for calculating the dry conditions temperature profile, and an approximation is used for calculation of the temperature profile under wet conditions. The lowest allowable outdoor temperature increases rapidly for increasing relative humidity up to approximately 30%, at which point it tapers off slowly. The results also show that condensation in the heat exchanger increases the lowest allowed temperature in comparison to an identical heat exchanger with no condensation. Lastly, the results show that the distance between plates change the frost limit curve considerably, with a smaller distance between plates being worse for frost risks.

Place, publisher, year, edition, pages
2022.
Series
TRITA-ABE-MBT ; 22640
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-317450OAI: oai:DiVA.org:kth-317450DiVA, id: diva2:1694867
External cooperation
Bravida; Uponor
Supervisors
Examiners
Available from: 2022-09-12 Created: 2022-09-12

Open Access in DiVA

fulltext(1979 kB)1508 downloads
File information
File name FULLTEXT01.pdfFile size 1979 kBChecksum SHA-512
cdb486ff44a71d9e4fba865cb8068ef5b02e4e62346b048f8de0f340cfa97207febabf7ba85ae6afd0d27273b4f2dfe5201e5ddc7c1ab543d1ede371bd329245
Type fulltextMimetype application/pdf

By organisation
Concrete Structures
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 1535 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 1349 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf