Windows of Opportunities: Orientation, Sizing and PV-Shading of the Glazed Area to Reduce Cooling Energy Demand in Sub-Sahara Africa
Univ Gävle, Dept Bldg Engn Energy Syst & Sustainabil Sci, S-80176 Gävle, Sweden..
Univ Gävle, Dept Bldg Engn Energy Syst & Sustainabil Sci, S-80176 Gävle, Sweden..
Univ Gävle, Dept Bldg Engn Energy Syst & Sustainabil Sci, S-80176 Gävle, Sweden..
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Sustainable Buildings. KTH Royal Inst Technol, Dept Civil & Architectural Engn, S-10044 Stockholm, Sweden..ORCID iD: 0000-0003-1285-2334
Show others and affiliations
2023 (English)In: Energies, E-ISSN 1996-1073, Vol. 16, no 9, p. 3834-, article id 3834Article in journal (Refereed) Published
Abstract [en]

In hot climates, such as sub-Sahara Africa, window sizing and orientation pose challenges as they add, through solar insolation, to the building cooling energy demand and thus the cause of indoor overheating risk. This risk can be reduced through passive building-design-integrated measures, e.g., optimizing the window size, orientation and solar shading strategies. Through an IDA-ICE building performance simulation tool, the current study explores the impact of window size, optimization and building-integrated PV panels as shading strategies on cooling energy demands in three cities (Niamey, Nairobi and Harare) in sub-Sahara Africa. Results show that thermal comfort and cooling energy demand are sensitive to a window-to-wall ratio (WWR) > 70%, while the need for artificial lighting is negligible for a WWR > 50%, particularly in the north for cities in the Southern hemisphere and the south in the Northern hemisphere. A WWR > 70% in the east and west should be avoided unless shading devices are incorporated. Internal blinds perform better in improving occupant thermal comfort but increase artificial lighting while integrating PV panels, as external shading overhangs reduce cooling energy but also produce energy that can be utilized for building services, such as air conditioning. In this study, the results and implications of the optimization of window size, orientation and building-integrated shading and operation are discussed.

Place, publisher, year, edition, pages
MDPI AG , 2023. Vol. 16, no 9, p. 3834-, article id 3834
Keywords [en]
glazing area, window shading, cooling energy demand, thermal comfort, building-integrated photovoltaics
National Category
Energy Systems Building Technologies
Identifiers
URN: urn:nbn:se:kth:diva-327393DOI: 10.3390/en16093834ISI: 000987072000001Scopus ID: 2-s2.0-85159341251OAI: oai:DiVA.org:kth-327393DiVA, id: diva2:1759671
Note

QC 20230526

Available from: 2023-05-26 Created: 2023-05-26 Last updated: 2023-08-28Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Liu, Wei

Search in DiVA

By author/editor
Liu, Wei
By organisation
Sustainable Buildings
In the same journal
Energies
Energy SystemsBuilding Technologies

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 91 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf