Electrohydraulic Vascular Compression Device (e-VaC) with Integrated Sensing and Controls
Show others and affiliations
2023 (English)In: Advanced Materials Technologies, E-ISSN 2365-709X, Vol. 8, no 4, p. 2201196-, article id 2201196Article in journal (Refereed) Published
Abstract [en]

Right ventricular (RV) failure remains a significant clinical burden particularly during the perioperative period surrounding major cardiac surgeries, such as implantation of left ventricular assist devices (LVADs), bypass procedures or valvular surgeries. Device solutions designed to support the function of the RV do not keep up with the pace of development of left-sided solutions, leaving the RV vulnerable to acute failure in the challenging hemodynamic environments of the perioperative setting. This work describes the design of a biomimetic, soft, conformable sleeve that can be prophylactically implanted on the pulmonary artery to support RV ventricular function during major cardiac surgeries, through afterload reduction and augmentation of flow. Leveraging electrohydraulic principles, a technology is proposed that is non-blood contacting and obviates the necessity for drivelines by virtue of being electrically powered. In addition, the integration of an adjacent is demonstrate, continuous pressure sensing module to support physiologically adaptive control schemes based on a real-time biological signal. In vitro experiments conducted in a pulsatile flow-loop replicating physiological flow and pressure conditions show a reduction of mean pulmonary arterial pressure of 8 mmHg (25% reduction), a reduction in peak systolic arterial pressure of up to 10 mmHg (20% reduction), and a concomitant 19% increase in diastolic pulmonary flow. Computational simulations further predict substantial augmentation of cardiac output as a result of reduced RV ventricular stress and RV dilatation. 

Place, publisher, year, edition, pages
Wiley , 2023. Vol. 8, no 4, p. 2201196-, article id 2201196
Keywords [en]
continuous sensing, electrohydraulic actuator, mechanical cardiac support, right ventricular failure, Artificial heart, Biomimetics, Cardiovascular surgery, Failure (mechanical), Heart, Hydraulic actuators, Left ventricular assist devices, Mechanical actuators, % reductions, Cardiac-surgery, Compression devices, Electro-hydraulic actuator, Electro-hydraulics, Mechanical, Right ventricular, Hydraulics
National Category
Medical Engineering
Identifiers
URN: urn:nbn:se:kth:diva-329003DOI: 10.1002/admt.202201196ISI: 000882538300001Scopus ID: 2-s2.0-85142064423OAI: oai:DiVA.org:kth-329003DiVA, id: diva2:1767651
Note

QC 20230614

Available from: 2023-06-14 Created: 2023-06-14 Last updated: 2023-06-14Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Dual, Seraina A.

Search in DiVA

By author/editor
Dual, Seraina A.
By organisation
Biomedical Engineering and Health Systems
In the same journal
Advanced Materials Technologies
Medical Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 121 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf