kth.sePublications
Change search
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf
Fuktegenskaper för materialet lerputs: Hur fungerar lerputs som fuktbuffrande material?
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Building Technology and Design.
2024 (Swedish)Independent thesis Basic level (degree of Bachelor), 10 credits / 15 HE creditsStudent thesisAlternative title
Moisture properties of clay plaster : How does clay plaster function as a moisture-buffering material? (English)
Abstract [sv]

Idag består majoriteten av skadorna inom den svenska byggbranschen av fuktskador. De kan skapa ekonomiska kostnader, hälsoproblem och påverka miljön mycket negativt. För att minska antal fuktskador används ofta fukttekniker och aktivt fuktarbete. Även aspekter som smartamaterialval kan påverka förekomsten av fuktskador i byggnader. Det kan därför vara bra att undersöka fler material än de som vanligtvis används idag, för att se om fler material kan användas då det kan ge positiva effekter för ekonomi, miljö och hälsa. Ett material som idag inte är vanligt i svenskt byggande är lerputs, det finns däremot utländska studier om materialet och lerjord har funnits som material under lång tid. I utlandet och från enskilda försök har lerputsvisat sig kunna ha positiva egenskaper gällande fuktbuffring. Fåtal svenska studier och undersökningar gör att materialet anses obeprövat och används därför sällan i Sverige.Den här uppsatsen studerar hur lerputs fungerar som ett fuktbuffrande material. Arbetet baseras i huvudsak på beräkningar med programmet WUFI. Olika miljöer har studerats i WUFI genom att bygga upp fem olika fall med varierande egenskaper, där ett rum med lerputs och ett rum utan lerputs ingår i varje fall. Från fallen analyseras lerputs fuktbuffringsförmåga och jämförs med tidigare studier. Anledningen till att denna studie görs är för att öka kunskap om materialet lerputs och undersöka dess fuktbuffrande egenskaper. Arbetet är avgränsat till teoretiskabedömningar och fortsatta studier är nödvändigt för att med större säkerhet kunna bedöma materialet. I rapporten framgår att lerputs är ett fuktbuffrande material, det jämnar ut rumsluftens relativa fuktighet och fungerar bra vid låga, men ännu bättre vid höga, relativa fuktigheter hos den ventilerade luften. Storlek på rum och RF hos den ventilerade luften påverkar fuktbuffringen, därav är lerputs väldigt fuktbuffrande i vissa förhållanden. I studerat fall med våtrumsliknandemiljö, minskas variationerna på RF från 50 – 87 % i rummet utan lerputs till 66 – 71 % i rummet med lerputs. I rummet med lerputs minskar RF så mycket att det inte når en kritisk nivå ochdärav kan materialet vara användbart i ett våtrum.

Abstract [en]

Today, most damages within the Swedish construction industry consist of moisture damages. Moisture damages can create economic costs, health problems, and negatively impact the environment. To reduce the amount of moisture damages, moisture specialists and active moisture management are often used. Although, smart material choices can also influence the occurrence of moisture damages in buildings. Therefore, it can be beneficial to investigate othermaterials than those commonly used today, to see if more materials can be utilized, as this can have positive effects on economy, environment and health. Clay plaster is a material that is not commonly used in Swedish construction today. However, foreign studies have been done aboutthe material and other clay structures has been used for a long period of time. From other countries and individual trials, the material has shown positive properties regarding its moisture buffering capabilities. However, without Swedish studies and investigations, the material is considered untested, and few choose to use it.This thesis reviews how clay plaster works as a moisture-buffering material. This thesis ismostly based on calculations from the program WUFI. Various environments are studied inWUFI by creating five different cases with varying properties, where each case includes one room with clay plaster and one without clay plaster. Based on the cases, the moisture buffering capacity of clay plaster is analyzed and compared with previous studies. The reason for conducting this study is to draw attention to the material clay plaster and investigate if it is moisture-buffering. The work is limited to theoretical assessments, and further studies are necessary to confidently evaluate the material.The report shows that clay plaster works as a moisture-buffering material. It evens out the indoor relative humidity and works well at low, but even better at high, relative humidity of the ventilated air. The size of the room and the relative humidity of the ventilated air greatly affect the moisture buffering; hence, clay plaster is very moisture-buffering under certain conditions. In bathroom-like environments, the variations in relative humidity are reduced from 50 – 87 % in the room without clay plaster, to 66 – 71 % in the room with clay plaster. In the room with clay plaster, the relative humidity decreases so much that it does not reach a critical level, making the material very useful in a wet room.

Place, publisher, year, edition, pages
2024.
Series
TRITA-ABE-MBT ; 24601
Keywords [en]
Clay Plaster, Moisture, Moisture Buffering, WUFI, Indoor Air.
Keywords [sv]
Lerputs, Fukt, Fuktbuffring, WUFI, Inomhusluft.
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-350194OAI: oai:DiVA.org:kth-350194DiVA, id: diva2:1882959
Supervisors
Examiners
Available from: 2024-07-08 Created: 2024-07-08

Open Access in DiVA

fulltext(3972 kB)94 downloads
File information
File name FULLTEXT01.pdfFile size 3972 kBChecksum SHA-512
bc93debb5a061bd30344a4833307b9c6b24a378a2a52d64a5215764672938bce600e2243fa06c639ca1affbbc5e29528c274298c608e1a1e5a4993372583d6a1
Type fulltextMimetype application/pdf

By organisation
Building Technology and Design
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 95 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 542 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf