Detection of Room Occupancy in Smart Buildings
Dept. of Radio Electronics, Brno University of Technology, Czechia.
Dept. of Radio Electronics, Brno University of Technology, Czechia.
Institute of New Imaging Technologies, University Jaume I, Spain.
KTH, School of Architecture and the Built Environment (ABE), Sustainable development, Environmental science and Engineering, Sustainability Assessment and Management. Digital Futures, Climate Action Center.ORCID iD: 0000-0002-7480-0858
Show others and affiliations
2024 (English)In: Radioengineering, ISSN 1210-2512, E-ISSN 1805-9600, Vol. 33, no 3, p. 432-441Article in journal (Refereed) Published
Abstract [en]

Recent advancements in occupancy and indoor environmental monitoring have encouraged the development of innovative solutions. This paper presents a novel approach to room occupancy detection using Wi-Fi probe requests and machine learning techniques. We propose a methodology that splits occupancy detection into two distinct subtasks: personnel presence detection, where the model predicts whether someone is present in the room, and occupancy level detection, which estimates the number of occupants on a six-level scale (ranging from 1 person to up to 25 people) based on probe requests. To achieve this, we evaluated three types of neural networks: CNN (Convolutional Neural Network), LSTM (Long Short-Term Memory), and GRU (Gated Recurrent Unit). Our experimental results show that the GRU model exhibits superior performance in both tasks. For personnel presence detection, the GRU model achieves an accuracy of 91.8%, outperforming the CNN and LSTM models with accuracies of 88.7% and 63.8%, respectively. This demonstrates the effectiveness of GRU in discerning room occupancy. Furthermore, for occupancy level detection, the GRU model achieves an accuracy of 75.1%, surpassing the CNN and LSTM models with accuracies of 47.1% and 52.8%, respectively. This research contributes to the field of occupancy detection by providing a cost-effective solution that utilizes existing Wi-Fi infrastructure and demonstrates the potential of machine learning techniques in accurately classifying room occupancy.

Place, publisher, year, edition, pages
Brno University of Technology , 2024. Vol. 33, no 3, p. 432-441
Keywords [en]
energy savings, machine learning, Occupancy detection, probe requests, Wi-Fi
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-352212DOI: 10.13164/re.2024.0432ISI: 001292738300010Scopus ID: 2-s2.0-85200274352OAI: oai:DiVA.org:kth-352212DiVA, id: diva2:1892395
Note

QC 20240905

Available from: 2024-08-26 Created: 2024-08-26 Last updated: 2024-09-05Bibliographically approved

Open Access in DiVA

fulltext(1012 kB)60 downloads
File information
File name FULLTEXT01.pdfFile size 1012 kBChecksum SHA-512
234604e2a024eb7c48d1f0057dc7668b1bd7ba49915138dd932addd82ba1cf9b986f91c6c65e9fa81faea85d2d7dca54e99e6e489a807b4caae2fe543bdce625
Type fulltextMimetype application/pdf

Other links

Publisher's full textScopus

Authority records

Azizi, Shoaib

Search in DiVA

By author/editor
Azizi, Shoaib
By organisation
Sustainability Assessment and Management
In the same journal
Radioengineering
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 60 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 252 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf