Application and analysis of Optimum PMU Placement methods with application to State Estimation Accuracy
KTH, School of Electrical Engineering (EES), Industrial Information and Control Systems.ORCID iD: 0000-0003-4386-3781
KTH, School of Electrical Engineering (EES), Industrial Information and Control Systems.ORCID iD: 0000-0003-3014-5609
2009 (English)In: 2009 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-8, New York: IEEE , 2009, p. 580-586Conference paper, Published paper (Refereed)
Abstract [en]

Phasor measurement units (PMU) coupled with high speed and bandwidth communication infrastructure holds great promise for future power system control and operation. The geographic location of the PMUs within the power system naturally affects the value added by PMUs to one specific application in power grid control and operation. Optimization of placement has been the subject of much analysis and research. This paper compares one PMU placement method targeting enhancement of state estimation accuracy with the current PMU deployment method utilized in Svenska Kraftnat (SvK), the Swedish Transmission System Operator. The possible estimation improvement applying this optimum placement algorithm is further studied while more PMUs are involved. Considering that the deployment of PMUs within SvK's grid is still limited, the study has been performed in a simulation environment. The paper contains a brief description of the simulation platform and the assumptions made during the work as well. The analysis shows that there are considerable gains to be made in estimator accuracy if the PMUs are placed in accordance with this method when compared to the current placement strategy. It could also be observed when the PMU monitored buses reaches a certain number in the entire network, the further introduction of phasor measurements will not be as effective in estimation accuracy improvement.

Place, publisher, year, edition, pages
New York: IEEE , 2009. p. 580-586
Series
IEEE Power and Energy Society General Meeting-PESGM
Keywords [en]
Estimation accuracy, phasor measurement unit, phasor measurement unit placement, state estimation
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-30145DOI: 10.1109/PES.2009.5275241ISI: 000275524900094Scopus ID: 2-s2.0-71849111106ISBN: 978-1-4244-4240-9 (print)OAI: oai:DiVA.org:kth-30145DiVA, id: diva2:401857
Conference
General Meeting of the IEEE-Power-and-Energy-Society. Calgary, CANADA, JUL 26-30, 2009
Available from: 2011-03-04 Created: 2011-02-21 Last updated: 2022-06-25Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Zhu, KunNordström, Lars

Search in DiVA

By author/editor
Zhu, KunNordström, Lars
By organisation
Industrial Information and Control Systems
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetric score

doi
isbn
urn-nbn
Total: 120 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf