Run-around coil ventilation heat recovery system: A comparative study between different system configurations
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Applied Thermodynamics and Refrigeration. (Uppvärmning och ventilation)ORCID iD: 0000-0003-3194-1762
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Applied Thermodynamics and Refrigeration.ORCID iD: 0000-0001-7354-6643
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Applied Thermodynamics and Refrigeration. (Uppvärmning och ventilation)ORCID iD: 0000-0003-3896-2443
2010 (English)In: ICAE 2010 – International conference on Applied energy – Singapore 21‐23 April 2010, 2010Conference paper, Published paper (Refereed)
Abstract [en]

The energy performance of buildings with considerable annual heat load is dependent on the ventilation air change rates (ACH). Buildings utilized for commercial use often have high ACH and therefore high annual heat load. In order for these buildings to have a reasonable energy performance a heat recovery system is often used to recover heat from the extraction air to the makeup air. There are different variations of these systems; one that is frequently used in Sweden is a run around coil heat recovery system.

The present paper summarizes the findings from the previous studies, and presents a comparative study, for three different cases; the traditional run-around coil heat recovery system; with a three stage on/off controlled heat pump retrofitted into the system; and with a variable capacity heat pump retrofitted into the system.

Annual modeling shows that by retrofitting a well-designed 3 stage heat pump to the system the annual heat recovery rate for the Stockholm Case can be increased from 47 % to 65 %. For the retrofitted variable capacity heat pump the numbers for the Stockholm Case is an improvement of annual heat recovery from 47 % to 66 %.

The modeling also shows that a well designed variable heat pump can cover 81 % of the ventilation heating demand and a well designed multi stage heat pump 77 % of the demand.

Place, publisher, year, edition, pages
2010.
Keywords [en]
Run-around coil, ventilation heat recovery, performance factors, retrofitted heat pump.
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:kth:diva-75587OAI: oai:DiVA.org:kth-75587DiVA, id: diva2:490648
Conference
ICAE 2010 – International conference on Applied energy
Note
QC 20120206Available from: 2012-02-06 Created: 2012-02-06 Last updated: 2022-06-24Bibliographically approved

Open Access in DiVA

Run-around coil ventilation heat recovery system: A comparative study between different system configurations(483 kB)9616 downloads
File information
File name FULLTEXT01.pdfFile size 483 kBChecksum SHA-512
0bb8ed604c647034ab7d01dd9512e44fc0c90d40bd544a2066ed9e801e82bf80cb39ae62a3fb6770af3e1bd675450175d324505281ca640a8be0bd5671516ba2
Type fulltextMimetype application/pdf

Other links

Conference website

Authority records

Wallin, JörgenMadani, HatefClaesson, Joachim

Search in DiVA

By author/editor
Wallin, JörgenMadani, HatefClaesson, Joachim
By organisation
Applied Thermodynamics and Refrigeration
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar
Total: 9721 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 419 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf