The influence of brine flow on the flow boiling refrigerant heat transfer coefficient in a compact brazed plate heat exchanger
KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Applied Thermodynamics and Refrigeration. KTH, School of Industrial Engineering and Management (ITM), Energy Technology, Sustainable Building Systems.ORCID iD: 0000-0003-3896-2443
2005 (English)In: International Journal of Heat Exchangers, ISSN 1524-5608, Vol. 6, no 1, p. 35-54Article in journal (Refereed) Published
Abstract [en]

The present article investigates the heat transfer coefficient on the refrigerant side in an compact brazed plate heat exchanger used as evaporator with different brine flows. The experimental equipment consisted of a test rig, simulating a domestic heat pump. Two different heat loads were tested, 5 kW and 10 kW, which corresponds to approx. 2.5 kW/m2 and 5.0 kW/m 2. The inlet quality to the evaporator was kept within 0.18 - 0.20. The pressure was kept within 2.93 - 2.97 bar(a) and R134a was used as refrigerant. The experiment showed for both heat loads a significant increase in the refrigerant area averaged heat transfer coefficient with increasing brine flow. It may be concluded that the temperature profile on the brine side has a significant influence on the refrigerant area averaged heat transfer coefficient. It is suggested that the higher wall superheat on the refrigerant side near the inlet of refrigerant is enhancing the heat transfer.

Place, publisher, year, edition, pages
2005. Vol. 6, no 1, p. 35-54
National Category
Energy Engineering
Identifiers
URN: urn:nbn:se:kth:diva-81064Scopus ID: 2-s2.0-14744299964OAI: oai:DiVA.org:kth-81064DiVA, id: diva2:497057
Note
QC 20120227Available from: 2012-02-10 Created: 2012-02-10 Last updated: 2022-06-24Bibliographically approved

Open Access in DiVA

No full text in DiVA

Scopus

Authority records

Claesson, Joachim

Search in DiVA

By author/editor
Claesson, Joachim
By organisation
Applied Thermodynamics and RefrigerationSustainable Building Systems
Energy Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 518 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf