Stresses in water filled concrete pools within nuclear facilities subjected to seismic loads
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Concrete Structures. Vattenfall R&D.
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Concrete Structures.ORCID iD: 0000-0002-8000-6781
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Concrete Structures.ORCID iD: 0000-0002-4015-3373
KTH, School of Architecture and the Built Environment (ABE), Civil and Architectural Engineering, Concrete Structures.ORCID iD: 0000-0001-8336-1247
2014 (English)In: Nordic Concrete Research, ISSN 0800-6377, no 51, p. 43-62Article in journal (Refereed) Published
Abstract [en]

This paper presents a study on water filled pools within nuclear facilities subjected to seismic loads. The type of structure studied is an elevated rectangular concrete tank, supported by the reactor containment, which is a high cylindrical concrete structure. Seismic analysis is performed using finite element models, accounting for fluid-structure interaction (FSI) between the water and the concrete structure. The stresses in a concrete pool are calculated, also investigating the changes in stresses as additional cross-walls are added. The effects from earthquakes dominated by low and high frequencies are evaluated, representative for conditions at the West coast of North America and Northern Europe, respectively. It is shown that the coupled fluid-structure systems have more significant modes in the high frequency range compared to the models without water, that is, for frequencies at which the Northern European type earthquake has significant energy compared to the Western North American earthquake. The seismic analyses show that the relative increase of hydrodynamic pressure is higher when the outer walls of the pool are stiffened due to the inclusion of additional cross-walls. With the inclusion of additional cross-walls, modes with lower natural frequencies, although still relatively high, become more important for the hydrodynamic pressure response. Leading to a higher stress response in the outer walls of the pool for models including the additional cross-walls compared to models without cross-walls. The study indicates that the effect from fluid-structure interaction is of great importance also for seismic loads with relatively high-frequency content.

Place, publisher, year, edition, pages
2014. no 51, p. 43-62
National Category
Infrastructure Engineering
Identifiers
URN: urn:nbn:se:kth:diva-145402OAI: oai:DiVA.org:kth-145402DiVA, id: diva2:718068
Note

QC 20150211. Updated from manuscript to article in journal

Available from: 2014-05-19 Created: 2014-05-19 Last updated: 2022-09-13Bibliographically approved
In thesis
1. Seismic high-frequency content loads on structures and components within nuclear facilities
Open this publication in new window or tab >>Seismic high-frequency content loads on structures and components within nuclear facilities
2014 (English)Licentiate thesis, comprehensive summary (Other academic)
Abstract [en]

Sweden is generally considered to be a low seismicity area, but for structures within nuclear power facilities, the safety level demand with respect to seismic events are high and thus, these structures are required to be earthquake-resistant. The seismic hazard is here primarily considered to be associated with near-field earthquakes. The nuclear power plants are further founded on hard rock and the expected ground motions are dominated by high frequencies. The design earthquake considered for the nuclear facilities has an annual probability of 10-5 events, that is, the probability of occurrence is once per 100 000 years. The focus of the study is the seismic response of large concrete structures for the nuclear power industry, with regard not only to the structure itself but also to non-structural components attached to the primary structure, and with emphasis on Swedish conditions. The aim of this licentiate thesis is to summarize and demonstrate some important aspects when the seismic load is dominated by high frequencies. Additionally, an overview of laws, regulations, codes, standards, and guidelines important for seismic analysis and design of nuclear power structures is provided.

The thesis includes two case studies investigating the effect of seismic high-frequency content loads. The first study investigates the influence of gaps in the piping supports on the response of a steel piping system subjected to a seismic load dominated by high amplitudes at high frequencies. The gaps are found in the joints of the strut supports or are gaps between the rigid box supports and the pipe. The piping system is assessed to be susceptible to high-frequency loads and is located within the reactor containment building of a nuclear power plant. The stress response of the pipe and the acceleration response of the valves are evaluated. The second study investigates the effect of fluid-structure interaction (FSI) on the response of an elevated rectangular water-containing concrete pool subjected to a seismic load with dominating low and high frequencies, respectively. The pool is located within the reactor containment building of a boiling water reactor at a nuclear power plant. The hydrodynamic pressure distribution is evaluated together with the stress distribution in the walls of the tank.

From the two case studies, it is evident that the response due to a seismic load dominated by high frequencies and low frequencies, respectively, is different. Although the seismic high-frequency load may be considered non-damaging for the structure, the effect may not be negligible for non-structural components attached to the primary structure. Including geometrical non-linear effects such as gaps may however reduce the response. It was shown that the stress response for most of the pipe elements in the first case study was reduced due to the gaps. It may also be that the inclusion of fluid-structure interaction effects changes the dynamic properties of a structural system so that it responds significantly in the high frequency range, thus making it more vulnerable to seismic loads dominated by high frequencies. In the second case study, it was shown that even for a seismic load with small amplitudes and short duration, but with dominating high-frequency content, as the Swedish 10-5 design earthquake, the increase of the dynamic response as fluid-structure interaction is accounted for is significant.

Place, publisher, year, edition, pages
Stockholm: KTH Royal Institute of Technology, 2014. p. xii, 52
Series
TRITA-BKN. Bulletin, ISSN 1103-4270 ; 123
Keywords
Nuclear power plant, Earthquake, Seismic high frequencies, Fluid-structure interaction, Piping, Concrete, Pool
National Category
Civil Engineering
Identifiers
urn:nbn:se:kth:diva-145403 (URN)
Presentation
2014-06-09, Sal B26, Brinellvägen 23, KTH Byggvetenskap, Stockholm, 10:00 (English)
Opponent
Supervisors
Note

QC 20150519

Available from: 2014-05-19 Created: 2014-05-19 Last updated: 2022-09-13Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

pdf

Authority records

Rydell, CeciliaGasch, TobiasEriksson, DanielAnsell, Anders

Search in DiVA

By author/editor
Rydell, CeciliaGasch, TobiasEriksson, DanielAnsell, Anders
By organisation
Concrete Structures
In the same journal
Nordic Concrete Research
Infrastructure Engineering

Search outside of DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric score

urn-nbn
Total: 348 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf