Design phasor data concentrator as adaptive delay buffer for wide-area damping control
KTH, School of Electrical Engineering (EES), Industrial Information and Control Systems.ORCID iD: 0000-0003-3014-5609
2015 (English)In: Electric power systems research, ISSN 0378-7796, E-ISSN 1873-2046, Vol. 127, p. 22-31Article in journal (Refereed) Published
Abstract [en]

Phasor Data Concentrators (PDCs) are employed to aggregate data frames from multiple Phasor Measurement Units (PMUs) with the same time-stamp into data packets. This function is an essential step in the utilization of PMU data in Wide-Area Monitoring and Control (WAMC) system. This is facilitated by assigning a fixed and heuristically decided wait time to the PDC buffer. The processed PMU data packets are sent to WAMC applications or similarly PDCs at higher hierarchies in the WAMC system when either a PDC buffer is full or its wait time has passed. In this paper, two methods to configure adaptive PDC wait time based on recent PMU traffic delay patterns are proposed. The purpose is to reduce the frequency of performing delay compensations in wide-area damping control system. With the adaptive PDC delay buffer in place, the wide-area damping controller only switches its gain once every five seconds, given the studied PMU traffic delay scenarios, instead of the current practice which requires the control gain to be adapted on a per PMU data frame basis, e.g., 50 or 60 times every second. The proposed methods offer a perspective to efficiently utilize the supporting Information and Communication Technology infrastructure with the purpose to simplify the design and implementation of wide-area damping control system.

Place, publisher, year, edition, pages
2015. Vol. 127, p. 22-31
Keywords [en]
Communication delay, Delay buffer, Phasor Data Concentrator, Phasor Measurement Unit, Power system oscillation, Power system Stability, Wide-Area Monitoring and Control system
National Category
Other Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-170213DOI: 10.1016/j.epsr.2015.05.002ISI: 000358810300003Scopus ID: 2-s2.0-84930625604OAI: oai:DiVA.org:kth-170213DiVA, id: diva2:827636
Note

QC 20150629

Available from: 2015-06-29 Created: 2015-06-29 Last updated: 2022-06-23Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopus

Authority records

Nordström, Lars

Search in DiVA

By author/editor
Nordström, Lars
By organisation
Industrial Information and Control Systems
In the same journal
Electric power systems research
Other Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 173 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf