Modeling of Communication Infrastructure Compatible to Nordic 32 Power System
KTH, School of Electrical Engineering (EES), Centres, Swedish Centre of Excellence in Electric Power Engineering, EKC2. KTH, School of Electrical Engineering (EES), Industrial Information and Control Systems.ORCID iD: 0000-0002-6330-3055
KTH, School of Electrical Engineering (EES), Centres, Swedish Centre of Excellence in Electric Power Engineering, EKC2. KTH, School of Electrical Engineering (EES), Industrial Information and Control Systems.ORCID iD: 0000-0003-3946-7655
KTH, School of Electrical Engineering (EES), Industrial Information and Control Systems. (PSMIX)ORCID iD: 0000-0003-3014-5609
2016 (English)In: IEEE-Power-and-Energy-Society General Meeting 2016, IEEE, 2016Conference paper, Published paper (Refereed)
Abstract [en]

Smart Grid integrates communication and computationtechnologies into power systems. Research on interdisciplinarytopics between power system and communicationsystems requires models for both systems. There are severalpower system models available representing standard powersystems and real power systems. However, lacking of theircorresponding communication infrastructure information leadsthe difficulty of communication system modeling. In this paper,a communication infrastructure model compatible to Nordic 32power system model has been developed and presented. In thismodel, Wide Area Monitoring System (WAMS) is incorporatedwith Supervisor Control and Data Acquisition system. Theparameters of this model are based on the data from a Nordicelectric power utility. Validation of the model is performedthrough comparison of results from simulation and a previousempirical data study performed on the same utility network. Inadditional, this model is simulated by using different Qualityof Service (QoS) mechanism. The obtained results show thatcongestion management mechanisms introduce additional delayto the highest priority traffic slightly. But traffics with lowerpriority can be benefit from congestion management mechanisms.The proposed model can be widely used for other research onNordic 32 power system.

Place, publisher, year, edition, pages
IEEE, 2016.
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Identifiers
URN: urn:nbn:se:kth:diva-178167DOI: 10.1109/PESGM.2016.7741521ISI: 000399937901161Scopus ID: 2-s2.0-85001959389OAI: oai:DiVA.org:kth-178167DiVA, id: diva2:877668
Conference
IEEE PES GM 2016
Note

QC 20170313

Available from: 2015-12-07 Created: 2015-12-07 Last updated: 2022-06-23Bibliographically approved
In thesis
1. Quality Assurance of Time Critical Data Using Adaptive Data Delivery Mechanisms in Smart Grids
Open this publication in new window or tab >>Quality Assurance of Time Critical Data Using Adaptive Data Delivery Mechanisms in Smart Grids
2018 (English)Doctoral thesis, comprehensive summary (Other academic)
Abstract [en]

Smart grids are proposed to integrate renewable energy and to improve the efficiency of power system operation. The challenges of integrating renewable energy are the inherent fluctuations of generation which are difficult to predict which may lead to challenges to the safe operation of power systems. Improving the efficiency of power systems means they should be operated closer to their limits. To solve these challenges, advanced protection and control applications, have been proposed that increase the accuracy of reactions and reduce the response time to events and faults. However, not all the data required for these applications can be delivered by the conventional Supervisory Control And Data Acquisition (SCADA) systems. As an example, synchrophasor data are intended to be delivered via a Wide Area Monitoring and Control (WAMC) system, which can be seen as a parallel data delivery infrastructure to SCADA. As deployment of intelligent substation secondary devices such as Intelligent Electronic Devices (IEDs), Merging Units (MUs), and Phasor Measurement Units (PMUs), data volume and data resolution in the power systems is increasing. To flexibly share data in the power system, different data delivery architectures have been proposed. Flexible data sharing brings benefits of information resiliency from different data sources. But it also raises the requirements on cyber-security for protection of the smart grid applications. Such needs are in turn being gradually addressed by new cyber-security mechanisms.

In this thesis, the main quality attributes for time critical smart grid applications being; data accuracy, information resiliency, communication performance, and cyber-security and their interrelation are studied. Most previous research has been focused on assurance on one of these quality attributes, while in practical implementation the attributes are clearly related and interdependent. There is consequently a lack of study of the interactions between these quality attributes.

This thesis focuses on the interactions of three pairs of these four time critical data quality attributes. The hypothesis of the interaction of each pair has been formulated as research question which is answered in different sections of the thesis. The results of this thesis show that information resiliency can increase the data accuracy and enhance the communication performance assurance to the smart grid application. This is in the thesis shown by two of the contributions presented in this thesis, being the implementation and validation of an adaptive data source selection mechanism to realize at substation level and wide area system level separately. In addition, since cyber-security mechanisms can affect the communication performance, specifically latency, and a trade off between security and performance may be needed. A third contribution in the thesis is a framework incorporating these two time critical quality attributes consisting of  an adaptive cyber-security scheme which contributes to the incorporation of performance requirements.

Place, publisher, year, edition, pages
Stockholm: KTH Royal Institute of Technology, 2018. p. 69
Series
TRITA-EECS-AVL ; 2019:16
Keywords
time critical data quality, adaptive mechanisms, quality assurance, Smart Grid, information resiliency, data accuracy, end-to-end latency, cyber-security, substation automation, power system communication
National Category
Electrical Engineering, Electronic Engineering, Information Engineering
Research subject
Electrical Engineering; Industrial Information and Control Systems
Identifiers
urn:nbn:se:kth:diva-243862 (URN)978-91-7873-105-3 (ISBN)
Public defence
2019-03-13, F3, Lindstedtsvägen 26, Stockholm, 22:41 (English)
Opponent
Supervisors
Note

QC 20190208

Available from: 2019-02-08 Created: 2019-02-07 Last updated: 2022-06-26Bibliographically approved

Open Access in DiVA

No full text in DiVA

Other links

Publisher's full textScopusConference website

Authority records

Yiming, WuBabazadeh, DavoodNordström, Lars

Search in DiVA

By author/editor
Yiming, WuBabazadeh, DavoodNordström, Lars
By organisation
Swedish Centre of Excellence in Electric Power Engineering, EKC2Industrial Information and Control Systems
Electrical Engineering, Electronic Engineering, Information Engineering

Search outside of DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric score

doi
urn-nbn
Total: 612 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf