Gas monitoring system using ultrasound sensors
KTH, School of Electrical Engineering (EES), Microsystem Technology.
2011 (English)Independent thesis Advanced level (professional degree), 20 credits / 30 HE creditsStudent thesis
Abstract [en]

This thesis reports a collaboration between KTH Microsystem Technology Labs and Maquet critical care. Maquet is a company that produces medical ventilators and anesthesia machines. In an anesthesia machine it is important to monitor the anesthesia concentration that is delivered so that the delivered anesthesia concentration does not deviate from the desired concentration. Furthermore, in case of fail function there is a need to stop the delivery of anesthesia to the patient and flush the system. The anesthetic agent concentration is presently monitored with an infrared spectrometer. By using ultrasound technology it is possible to determine the volume concentration of a gas mixture by knowing the sound speed in the gases. Maquet has an ultrasound sensor that is developed to measure the oxygen concentration in air. This sensor was modified in order to measure nitrous oxide and anesthesia. The anesthesia concentration was measured by placing sensors upstream and downstream from the vaporizer. Using this ultrasound sensor system one can observe that the average discrepancy of the entire concentration range is ±0.84 % for Desflurane and 0.17 % for Isoflurane in relation to the infraredspectrometer sensor that is presently used in the anesthesia machine to monitor the anesthetic agent. Measurements show that the rise time of the ultrasound sensor varies when placing the sensor in different orientations with respect to the airway flow. It also show that by placing a flow restrictor that is used to force the airway flow in to the sensors measurement chamber reduces the rise time to a tenth of its previous value.

Place, publisher, year, edition, pages
2011.
Series
EES Examensarbete / Master Thesis ; XR-EE-MST 2011:002
National Category
Engineering and Technology
Identifiers
URN: urn:nbn:se:kth:diva-91814OAI: oai:DiVA.org:kth-91814DiVA, id: diva2:511273
Uppsok
Technology
Examiners
Available from: 2017-03-31 Created: 2012-03-20 Last updated: 2022-06-24Bibliographically approved

Open Access in DiVA

fulltext(2227 kB)1312 downloads
File information
File name FULLTEXT01.pdfFile size 2227 kBChecksum SHA-512
2bdda1356e1997aac38761c29fda642f80e0099d21da0b9fcde6d30e208b8ae38f647153589dd1558e0c423c339d5f0da6dabaf2f0c57f0bac6c9618e65dcfd8
Type fulltextMimetype application/pdf

By organisation
Microsystem Technology
Engineering and Technology

Search outside of DiVA

GoogleGoogle Scholar
Total: 1316 downloads
The number of downloads is the sum of all downloads of full texts. It may include eg previous versions that are now no longer available

urn-nbn

Altmetric score

urn-nbn
Total: 707 hits
CiteExportLink to record
Permanent link

Direct link
Cite
Citation style
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Other style
More styles
Language
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Other locale
More languages
Output format
  • html
  • text
  • asciidoc
  • rtf