Detection of Thrombosis in the Extracorporeal Membrane Oxygenation Circuit by Infrasound: Proof of Concept
KTH, Skolan för teknikvetenskap (SCI), Mekanik. KTH, Skolan för teknikvetenskap (SCI), Centra, Linné Flow Center, FLOW.
KTH, Skolan för teknikvetenskap (SCI), Mekanik. KTH, Skolan för teknikvetenskap (SCI), Centra, Linné Flow Center, FLOW.
2017 (engelsk)Inngår i: Artificial Organs, ISSN 0160-564X, E-ISSN 1525-1594, Vol. 41, nr 6, s. 573-579Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

As of today, there exist no reliable, objective methods for early detection of thrombi in the extracorporeal membrane oxygenators (ECMO) system. Within the ECMO system, thrombi are not always fixed to a certain component or location in the circuit. Thus, clot fragments of different shapes and consistencies may circulate and give rise to vibrations and sound generation. By bedside sound measurements and additional laboratory experiments (although not detailed herein), we found that the presence of particles (clots or aggregates and fragments of clots) can be detected by analyzing the strength of infra-sound (< 20 Hz) modes of the spectrum near the inlet and outlet of the centrifugal pump in the ECMO circuit. For the few patients that were considered in this study, no clear false positive or negative examples were found when comparing the spectral approach with clinical observations. A laboratory setup provided insight to the flow in and out of the pump, confirming that in the presence of particles a low-amplitude low-frequency signal is strongly amplified, enabling the identification of a clot.

sted, utgiver, år, opplag, sider
Wiley-Blackwell, 2017. Vol. 41, nr 6, s. 573-579
Emneord [en]
Clot detection, Centrifugal pump, Extracorporeal membrane oxygenation
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-210439DOI: 10.1111/aor.12782ISI: 000403152300011PubMedID: 27654663Scopus ID: 2-s2.0-84994138836OAI: oai:DiVA.org:kth-210439DiVA, id: diva2:1118477
Merknad

QC 20170630

Tilgjengelig fra: 2017-06-30 Laget: 2017-06-30 Sist oppdatert: 2017-07-03bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Søk i DiVA

Av forfatter/redaktør
Berg, NiclasWittberg, Lisa Prahl
Av organisasjonen
I samme tidsskrift
Artificial Organs

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 106 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf