Removing cosmic ray features from Raman map data by a refined nearest neighbor comparison method as a precursor for chemometric analysis.
2010 (engelsk)Inngår i: Applied Spectroscopy, ISSN 0003-7028, E-ISSN 1943-3530, Vol. 64, nr 2, s. 195-200Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

An algorithm to remove cosmic ray (CR) features from Raman spectra collected in mapping experiments using a charge-coupled device (CCD) is presented. Each spectrum is compared to spectra collected from adjacent points in space using correlation values. The most similar neighbor (MSN) spectrum is selected, offset, and used for identification of CRs. The offset values are defined in terms of the noise level for data with a low signal-to-noise ratio and in terms of the peak height for data with a high signal-to-noise ratio. Scaled intensity values of the MSN spectra are used for replacement of contaminated pixels, allowing for full recovery of underlying spectral features. The algorithm is applicable for any Raman map where the particle sizes within the analyzed mixture are larger than the sampling size or to any other data where the sampling is more frequent than the variation, e.g., time series or temperature profiles. Its application to several maps of pharmaceutical samples is discussed here. With an appropriate offset value for the MSN spectra, no misdetections occur, and all CRs more intense than the offset are removed, which includes the CRs that would have hampered subsequent chemometric analysis by methods such as principal component analysis (PCA).

sted, utgiver, år, opplag, sider
Sage Publications, 2010. Vol. 64, nr 2, s. 195-200
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-225449DOI: 10.1366/000370210790619528ISI: 000274506800010PubMedID: 20149281Scopus ID: 2-s2.0-77649197570OAI: oai:DiVA.org:kth-225449DiVA, id: diva2:1195422
Merknad

QC 20180416

Tilgjengelig fra: 2018-04-05 Laget: 2018-04-05 Sist oppdatert: 2018-04-16bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstPubMedScopus

Søk i DiVA

Av forfatter/redaktør
Cappel, Ute B
I samme tidsskrift
Applied Spectroscopy

Søk utenfor DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 22 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf