Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
CoST Of Wind
Katholieke Univ Leuven, Div ELECTA, Dept Elect Engn ESAT, Kasteelpk Arenberg 10,Bus 2445, B-3001 Heverlee, Belgium..
KTH, Skolan för elektro- och systemteknik (EES).
Katholieke Univ Leuven, Div ELECTA, Dept Elect Engn ESAT, Kasteelpk Arenberg 10,Bus 2445, B-3001 Heverlee, Belgium..
2010 (engelsk)Inngår i: 9TH INTERNATIONAL WORKSHOP ON LARGE-SCALE INTEGRATION OF WIND POWER INTO POWER SYSTEMS AS WELL AS ON TRANSMISSION NETWORKS FOR OFFSHORE WIND POWER PLANTS / [ed] Betancourt, U Ackermann, T, ENERGYNAUTICS GMBH , 2010, s. 753-758Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Large-scale offshore wind farms are getting more popular due to better wind conditions on the open sea. Several methods exist to connect offshore wind farms to the main electricity grid. In this paper a tool for estimating the overall connection costs for the link between the main grid and a wind farm is shown. The method compares both AC and DC connection options. In order to estimate the overall costs, several technical input parameters such as the transmitted power, the voltage level, connection requirements, etc. must be taken into consideration. Besides the technical aspects several non-technical aspects such as connection distance and prices for the used equipment have to be taken into account. Also the maintenance costs and costs for transmission losses as well as the energy that is delivered to the grid must be considered to get a realistic picture of the overall costs for different connection methods. This paper shows how these overall costs can be estimated and how a cost effective investment can be made. The described methods are implemented in an easy to use tool, which can be used by any project developer to get reasonable first estimate of the costs. The method is developed in Microsoft Excel (R).

sted, utgiver, år, opplag, sider
ENERGYNAUTICS GMBH , 2010. s. 753-758
Emneord [en]
Offshore wind farms, VSC HVDC, transmission losses, total transmission costs, breakeven distance
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-242800ISI: 000392554800105OAI: oai:DiVA.org:kth-242800DiVA, id: diva2:1290652
Konferanse
9TH INTERNATIONAL WORKSHOP ON LARGE-SCALE INTEGRATION OF WIND POWER INTO POWER SYSTEMS AS WELL AS ON TRANSMISSION NETWORKS FOR OFFSHORE WIND POWER PLANTS, Quebec City, CANADA, OCT 18-19, 2010
Merknad

QC 20190221

Tilgjengelig fra: 2019-02-21 Laget: 2019-02-21 Sist oppdatert: 2019-02-21bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Søk i DiVA

Av forfatter/redaktør
Van Hertem, Dirk
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 2 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf