Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Pre-standardisation of Interfaces between DC Circuit Breaker and Intelligent Electronic Device to Enable Multivendor Interoperability
KU Leuven/EnergyVille, Belgium.
Aberdeen Institute of Energy, UK.ORCID-id: 0000-0002-3285-0670
KU Leuven/EnergyVille, Belgium.ORCID-id: 0000-0002-7230-6784
KU Leuven/EnergyVille, Belgium.
Vise andre og tillknytning
2019 (engelsk)Konferansepaper, Oral presentation with published abstract (Fagfellevurdert)
Abstract [en]

DC circuit breakers (DCCBs) are one of the key components to facilitate large meshed HVDC grids. Driven by the needs for achieving high speed, low loss and low cost, various DCCB technologies have been proposed for HVDC applications. Unlike AC circuit breakers (ACCBs), some DCCBs provide a variety of functions, such as proactive opening or fault current limiting (FCL), mainly attributed to the high controllability of the power electronic switches used in such DCCBs. To enable these functions, the intelligent electronic devices (IEDs) are expected to provide signals steering these functions in addition to a trip command. Interoperability between IEDs and DCCBs from different vendors is considered feasible, but expected to be more complex than their AC counterparts, due to the different functions provided by various DCCB technologies. It is therefore crucial to understand which of the functions are essential to fulfil the requirements imposed in HVDC grid protection, and to standardise the interfaces between the IEDs and DCCBs to achieve multivendor interoperability between IEDs and DCCBs provided by different vendors. This paper first classifies the DCCB functions into minimally required and auxiliary ones based on reviewing the existing literature. Then, standardised interfaces between the IEDs and DCCBs are proposed to enable both types of DCCB functions. An example of such IED is implemented in PSCAD/EMTDC to demonstrate that the proposed interfaces are adequate to enable both minimally required and auxiliary functions using a four-terminal test system. Auxiliary functions of hybrid DCCBs, such as proactive opening, fault current limiting, fast reclosing and reopening, breaker failure internal detection and repeated O-C-O operation are demonstrated by simulations.

sted, utgiver, år, opplag, sider
2019.
Emneord [en]
HVDC grid protection, DC circuit breaker, intelligent electronic device, standardised interfaces, multivendor interoperability
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-252358OAI: oai:DiVA.org:kth-252358DiVA, id: diva2:1318791
Konferanse
CIGRE Symposium Aalborg, 4-7-Juni 2019 Denmark
Merknad

QC 20190819

Tilgjengelig fra: 2019-05-28 Laget: 2019-05-28 Sist oppdatert: 2019-10-18bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Personposter BETA

Jahn, Ilka

Søk i DiVA

Av forfatter/redaktør
Jovcic, DraganLeterme, WillemJahn, Ilka
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

urn-nbn

Altmetric

urn-nbn
Totalt: 109 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf