Energy Performance of Ground-source Heat Pump and Photovoltaic/thermal (PV/T) in Retrofitted and New Buildings: Two Case Studies Using Simulation and On-site Measurements
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Tillämpad termodynamik och kylteknik.ORCID-id: 0000-0001-8614-5806
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Tillämpad termodynamik och kylteknik.ORCID-id: 0000-0001-7354-6643
2020 (engelsk)Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

This paper aims to contribute by presenting calculated and measured electricity usage in two single-family case studies during the heating season of 2019-2020 located in Stockholm, Sweden. The electricity usage included consumption by heat pumps’ compressor to cover space heating and domestic hot water, auxiliary energy for fans and pumps, and ventilation system. The first case study was built in 1936 with an oil burner, which was renovated to a ground-source heat pump (GSHP) in 2015, and the second case study was a new building built in 2013 with a GSHP. The application of photovoltaic/thermal (PVT) systems in combination with GSHP was theoretically investigated for both case studies. Buildings were modelled using the energy simulation tool IDA Indoor Climate and Energy (ICE), and the model was validated against the measured electrical energy usage. PVT was designed to balance the maximum heat production with domestic hot water consumption during the summer months. Simulation results revealed that combining GSHP with 5 m2 grid-connected PVT gave 21% and 22% energy savings in case study 1 and case study 2, respectively. Employing a battery storage to store extra electricity production by PVT increased the energy savings to 24 % and 32 % for case study 1 and case study 2, respectively. Moreover, in both cases approximately half of the total annual domestic hot water need was prepared by 5 m2 PVT.

sted, utgiver, år, opplag, sider
2020.
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-279433OAI: oai:DiVA.org:kth-279433DiVA, id: diva2:1459759
Konferanse
BuildSim Nordic 2020 Conference
Merknad

QC 20200821

Tilgjengelig fra: 2020-08-20 Laget: 2020-08-20 Sist oppdatert: 2022-06-26bibliografisk kontrollert

Open Access i DiVA

fulltext(252 kB)234 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 252 kBChecksum SHA-512
ef8a0cb0f451172e9b826a21f0f669753d0f0d4d4c3149b8451125942a73dd681b766a06d997894563716493b919db70235fc8f5e739d67d067958b650990184
Type fulltextMimetype application/pdf

Person

Hesaraki, ArefehMadani Larijani, Hatef

Søk i DiVA

Av forfatter/redaktør
Hesaraki, ArefehMadani Larijani, Hatef
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 234 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 398 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf