Real-time Autofocus Algorithm in Laser Speckle Contrast Imaging
KTH, Skolan för kemi, bioteknologi och hälsa (CBH).
2023 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgaveAlternativ tittel
Autofokus i Realtid inom Laser Speckle Contrast Avbildning (svensk)
Abstract [en]

Microcirculation is defined as the blood flow in the smallest blood vessels. Laser speckle contrast imaging (LSCI) is a full field imaging technique that provides instantaneous 2-D perfusion maps of illuminated tissues based on speckle contrast. Perimed’s Perfusion Speckle Imager (PSI) is a medical device developed at Perimed AB that exploits LSCI to measure tissue blood perfusion. In this thesis work, a robust Autofocus (AF) algorithm for PSI was implemented. AF is a procedure to drive PSI camera to reach the depth of focus and acquire sharp images, that relies only on signal processing. Therefore, several Blind image sharpness assessment (BISA) methods, to judge the degree of image sharpness, were compared to choose which BISA method to incorporate in the algorithm. An optimized focus scanning technique was implemented to more efficiently find the depth of focus. When working with LSCI, speckle is a source of noise that destroys image content. Experiments were performed to study laser speckle filtration: digital filters were employed to attenuate the speckle noise that corrupted details in the acquired images. Finally, two methods to perform AF were provided. These procedures were proven practically with LED images. However, with laser source image information is corrupted by speckle despite the application of digital filters and AF remains a real challenge. Moreover, important hardware limitations require to be overcome to make the technique real-time. Focus motor speed should be higher to acquire images at different focus positions faster which could benefit the speed of the AF procedure and speckle filtration. 

sted, utgiver, år, opplag, sider
2023. , s. 92
Serie
TRITA-CBH-GRU ; 2023:010
Emneord [en]
Laser speckle contrast imaging, Autofocus, Blind image sharpness assessment, Speckle noise, Perimed’s Perfusion Speckle Imager
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-323329OAI: oai:DiVA.org:kth-323329DiVA, id: diva2:1731044
Eksternt samarbeid
Perimed AB
Fag / kurs
Medical Engineering
Utdanningsprogram
Master of Science - Medical Engineering
Veileder
Examiner
Tilgjengelig fra: 2023-01-26 Laget: 2023-01-25 Sist oppdatert: 2023-01-26bibliografisk kontrollert

Open Access i DiVA

fulltext(38396 kB)891 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 38396 kBChecksum SHA-512
6b913bb90fb795334d4e5ff7949bf73cee3a745f20cc5f605c428cae168672aae36e604d18c9497a9cc7ff9a7f2c4b415e828556f1298e554c18939a2fe91046
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 893 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 519 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf