Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Establishment of a Rapid Detection Method for Cadmium Ions via a Specific Cadmium Chelator N-(2-Acetamido)-Iminodiacetic Acid Screened by a Novel Biological Method
Development Center of Plant Germplasm Resources, College of Life Sciences, Shanghai Normal University, Shanghai 200234, China;; Department of Chemistry and Chemical Engineering, Yulin University, Yulin 719000, China;.
Development Center of Plant Germplasm Resources, College of Life Sciences, Shanghai Normal University, Shanghai 200234, China;.
Development Center of Plant Germplasm Resources, College of Life Sciences, Shanghai Normal University, Shanghai 200234, China;.
Department of Biological Chemistry, University of Michigan, Ann Arbor, MI 48109-0600, USA;, Ann Arbor.
Vise andre og tillknytning
2024 (engelsk)Inngår i: Foods, E-ISSN 2304-8158, Vol. 13, nr 17, artikkel-id 2684Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Heavy metal ions such as cadmium, mercury, lead, and arsenic in the soil cannot be degraded naturally and are absorbed by crops, leading to accumulation in agricultural products, which poses a serious threat to human health. Therefore, establishing a rapid and efficient method for detecting heavy metal ions in agricultural products is of great significance to ensuring the health and safety. In this study, a novel optimized spectrometric method was developed for the rapid and specific colorimetric detection of cadmium ions based on N-(2-Acetamido)-iminodiacetic acid (ADA) and Victoria blue B (VBB) as the chromogenic unit. The safety evaluation of ADA showed extremely low biological toxicity in cultured cells and live animals. The standard curve is y = 0.0212x + 0.1723, R2 = 0.9978, and LOD = 0.08 μM (0.018 mg/kg). The liner concentrations detection range of cadmium is 0.1–10 μM. An inexpensive paper strip detection method was developed with a detection limit of 0.2 μM to the naked eye and a detection time of less than 1 min. The method was successfully used to assess the cadmium content of rice, soybean, milk, grape, peach, and cabbage, and the results correlated well with those determined by inductively coupled plasma–mass spectrometry (ICP-MS). Thus, our study demonstrated a novel rapid, safe, and economical method for onsite, real-time detection of cadmium ions in agricultural products.

sted, utgiver, år, opplag, sider
MDPI AG , 2024. Vol. 13, nr 17, artikkel-id 2684
Emneord [en]
ADA, cadmium, food safety, rapid detection, VBB
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-353906DOI: 10.3390/foods13172684ISI: 001311058900001Scopus ID: 2-s2.0-85204141320OAI: oai:DiVA.org:kth-353906DiVA, id: diva2:1900981
Merknad

QC 20240925

Tilgjengelig fra: 2024-09-25 Laget: 2024-09-25 Sist oppdatert: 2024-09-25bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Person

Li, Jing

Søk i DiVA

Av forfatter/redaktør
Li, Jing
Av organisasjonen
I samme tidsskrift
Foods

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 29 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf