Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Standard orientation of the pelvis: Validation on a model and ten patients
Karolinska Institutet, Department of Clinical Science, Intervention and Technology, Division of Radiology.
Karolinska Institutet, Department of Clinical Science, Intervention and Technology, Division of Radiology.
Karolinska Institute, Department of Molecular Medicine and Surgery.
Karolinska Institute, Department of Molecular Medicine and Surgery.
Vise andre og tillknytning
2005 (engelsk)Inngår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 46, nr 1, s. 74-82Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Purpose: To validate an image post-processing method for re-orienting the pelvis in CT volumes to a standardized orientation in a model and in 10 patients. Material and Methods: Twenty-four CT volumes of a pelvic model and 10 pairs of postoperative total hip arthroplasty (THA) patient CT scans were rotated to a defined pelvic standard orientation and the rotation was recorded. For precision, a test-retest procedure was used. For accuracy, three exactly represented coordinate points were used. For clinical application, the standard orientation was used for calculating the direction of acetabular cup migration from a previous model study. Results: Precision of pelvic standard orientation, calculated as maximal directional error, was better than 1degrees in the model study and better than 1.5degrees in the patient study. Accuracy, expressed as angle between ideal and measured coordinate axes, was 0.1degrees for x, y, z axes. No measurable systematic errors were found. When applied to acetabular cup migration in the model, standardization of pelvic orientation had no significant effect on the measurements. Conclusion: Reorienting the pelvis during image post-processing was shown to be accurate. It enables measurements relative to the pelvis and minimizes the dependency of patient positioning.

sted, utgiver, år, opplag, sider
London, UK: Informa Healthcare, 2005. Vol. 46, nr 1, s. 74-82
Emneord [en]
CT, hip, arthroplasty, total hip-arthroplasty, acetabular component migration, semiautomated program, computed-tomography, ct, fusion, cup, anteversion, alignment
HSV kategori
Forskningsprogram
SRA - Informations- och kommunikationsteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-14561DOI: 10.1080/02841850510016063ISI: 000227276400012OAI: oai:DiVA.org:kth-14561DiVA, id: diva2:332602
Merknad
QC 20100525Tilgjengelig fra: 2010-08-05 Laget: 2010-08-05 Sist oppdatert: 2017-12-12bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Maguire Jr., Gerald Q.

Søk i DiVA

Av forfatter/redaktør
Maguire Jr., Gerald Q.Svensson, Lars E.
Av organisasjonen
I samme tidsskrift
Acta Radiologica

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 144 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf