Refrigerant mass charge distribution in a domestic refrigerator. Part I: Transient conditions
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Tillämpad termodynamik och kylteknik.
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Tillämpad termodynamik och kylteknik.ORCID-id: 0000-0002-9902-2087
2006 (engelsk)Inngår i: Applied Thermal Engineering, ISSN 1359-4311, E-ISSN 1873-5606, Vol. 26, nr 8-9, s. 829-837Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Experimental results are presented of the refrigerant mass charge distribution in a steadily cycling domestic refrigerator. In detail it is shown how the charge is displaced at compressor start-up and shut-down. At start-Lip it was found that the charge was temporarily displaced towards the condenser before returning to a steady state distribution in the latter part of the on-period. As a result, initially the evaporator was starved with a lowered evaporation temperature and a peak 10 degrees C superheat. The superheat disappeared within 3 min as the evaporator was gradually refilled with refrigerant. At shut-down the pressure equalised within 3 min as refrigerant was pushed into the evaporator from the condenser. The losses due to charge displacements were estimated to 11% (capacity) and 9% (efficiency). Possible ways to reduce the losses are discussed.

sted, utgiver, år, opplag, sider
2006. Vol. 26, nr 8-9, s. 829-837
Emneord [en]
domestic refrigerator, charge inventory, capillary tube, dynamic simulation, cycling losses, system, freezer
Identifikatorer
URN: urn:nbn:se:kth:diva-15551DOI: 10.1016/j.applthermaleng.2005.10.003ISI: 000236308200007Scopus ID: 2-s2.0-29244464681OAI: oai:DiVA.org:kth-15551DiVA, id: diva2:333592
Merknad
QC 20100525Tilgjengelig fra: 2010-08-05 Laget: 2010-08-05 Sist oppdatert: 2017-12-12bibliografisk kontrollert
Inngår i avhandling
1. Energy Efficiency Improvements in Household Refrigeration Cooling Systems
Åpne denne publikasjonen i ny fane eller vindu >>Energy Efficiency Improvements in Household Refrigeration Cooling Systems
2012 (engelsk)Doktoravhandling, med artikler (Annet vitenskapelig)
Abstract [en]

This thesis is based on eight articles all related to the characteristics of the cooling system and plate evaporator of a household refrigerator. Through these articles, knowledge is provided that can be used to increase the operational efficiency in household refrigeration. Papers A, B and C focus on heat transfer and pressure drop in a commonly used free convection evaporator – the plate evaporator. Applicable correlations are suggested on how to estimate the air side heat transfer, the refrigerant side pressure drop and the refrigerant side heat transfer. Papers D, E and F hold a unique experimental study of the refrigerant charge distribution in the cooling system at transient and steady state conditions. From this cyclic losses are identified and estimated and ways to overcome them are suggested. In paper G the topic “charging and throttling” is investigated in an unparalleled experimental study based on more than 600 data points at different quantities of charge and expansions device capacities. It results in recommendations on how to optimize the capillary tube length and the quantity of refrigerant charge. Finally, Paper H holds a thermographic study of the overall cooling system operating at transient conditions. Overall, a potential to lower the energy use by as much as 25 % was identified in the refrigerator studied. About 10 % was found on the evaporator’s air side. 1-2 % was identified as losses related to the edge effect of the evaporator plate. About 8 % was estimated to be cyclic losses. About 5 % was found in cycle length optimization.  It is believed that most of these findings are of general interest for the whole field of household refrigeration even though the results come from one type of refrigerator. Suggestions of simple means to reduce the losses without increasing the unit price are provided within the thesis

sted, utgiver, år, opplag, sider
Stockholm: KTH Royal Institute of Technology, 2012. s. 115
Serie
TRITA-REFR, ISSN 1102-0245 ; 12:02
Emneord
Household refrigerator, Domestic refrigerator, Free convection, Plate evaporator, Heat transfer, Flow boiling, Isobutane, R600a, Pressure drop, Two-phase, Cooling system, Charge inventory, Cyclic losses, Thermography
HSV kategori
Identifikatorer
urn:nbn:se:kth:diva-93061 (URN)978-91-7501-306-0 (ISBN)
Disputas
2012-04-27, F3, Lindstedtsvägen 26, Stockholm, 10:00 (engelsk)
Opponent
Veileder
Merknad

QC 20120411

Tilgjengelig fra: 2012-04-11 Laget: 2012-04-10 Sist oppdatert: 2014-02-11bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Palm, Björn E.

Søk i DiVA

Av forfatter/redaktør
Björk, Erik T.Palm, Björn E.
Av organisasjonen
I samme tidsskrift
Applied Thermal Engineering

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 263 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf