Methods for determining the spatial distribution of oxidation in ultra-high molecular-weight polyethylene prostheses
KTH, Skolan för industriell teknik och management (ITM), Materialvetenskap, Mekanisk metallografi.
2007 (engelsk)Inngår i: Polymer degradation and stability, ISSN 0141-3910, E-ISSN 1873-2321, Vol. 92, nr 3, s. 437-447Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Oxidative degradation is a well-known problem for UHMWPE used in prostheses. The aim of the present study has been to find suitable techniques to study the spatial distribution of this oxidation in 8 retrieved acetabular cups. The techniques used were visual examination using an optical microscope and computer scanner, FTIR mapping, imaging chemiluminescence, and staining with SO2 and HCl. The staining technique is based on a previous study which showed that by treating oxidized UHMWPE with SO2 followed by heat treatment, the hydroperoxides present in the sample react with the SO2 and discolor the sample. The intensity of this discoloring is, at low levels of oxidation, proportional to the amount of hydroperoxides and accordingly to the level of the oxidation. The same study also showed that staining a sample with hot HCl resulted in a brown discoloration which was proportional to the amount of carbonyls. It was found that the staining techniques do not give as much information about the chemical and physical changes in the material as FTIR mapping but have a great advantage in better spatial resolution of the oxidation and are also much quicker and easier to use. Imaging chemiluminescence turned out not to be a suitable method to use, compared to the other two, since it gives less information and is more difficult to interpret. When interpreting the results from the different techniques used, it was found that all cups showed the typical oxidation behavior of gamma sterilized UHMWPE. All cups but one showed substantial wear of the articulating surface but very little backside wear. Examination of the oxidation and whitening profile suggests that at least some of the oxidation must have occurred in vivo.

sted, utgiver, år, opplag, sider
2007. Vol. 92, nr 3, s. 437-447
Emneord [en]
UHMWPE, polyethylene, acetabular cup, oxidation, FTIR, SO2, in-vivo, imaging chemiluminescence, oxidized polyolefins, orthopedic uhmwpe, products, hydroperoxides, biodegradation, oxide
Identifikatorer
URN: urn:nbn:se:kth:diva-16458DOI: 10.1016/j.polymdegradstab.2006.11.016ISI: 000244983400012Scopus ID: 2-s2.0-33847046808OAI: oai:DiVA.org:kth-16458DiVA, id: diva2:334500
Merknad
QC 20100525Tilgjengelig fra: 2010-08-05 Laget: 2010-08-05 Sist oppdatert: 2017-12-12bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Søk i DiVA

Av forfatter/redaktør
Jonsson, Stefan
Av organisasjonen
I samme tidsskrift
Polymer degradation and stability

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 198 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf