On the influence of conductor heights and lossy ground in multi-conductor transmission lines for lightning interaction studies in railway overhead traction systems
Uppsala University.
Uppsala University.
Uppsala University.
Uppsala University. (EMC)ORCID-id: 0000-0002-1607-2493
2004 (engelsk)Inngår i: Electric power systems research, ISSN 0378-7796, E-ISSN 1873-2046, Vol. 71, nr 2, s. 186-193Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Railway overhead traction system is a classic example of scattered conductor configuration, where tracks and other wires form multi-conductor transmission lines (MTLs) with large variation in conductor heights above ground and they are spread across regions having different soil conditions. Lightning transient analysis in such systems has not received much attention earlier. Here we analyze the influence of conductor heights and lossy ground on the induced voltages in a two conductor MTLs for the case of a direct lightning strike. For transient analysis, modified time domain transient ground impedance expressions having better early and late time behavior was used. The dependence of transient ground impedance on conductor heights and ground resistivity are presented and discussed. The early time transient ground impedances are unaffected by ground resistivity but their decaying nature is highly dominated by ground resistivity. It is found, if one of the conductors is close to ground (a rail) and if it is at large vertical distance from struck conductor (an auxiliary power line), then with increasing ground resistivity the peak induced voltages in the conductor close to ground initially increase, then decrease and finally tend to remain constant (within 100-10,000 Omega m). This phenomenon is opposite to that compared to conductors that are close to each other with minimum vertical separation (two auxiliary power lines), where the peak induced voltages increase with increasing ground resistivity. The study focuses mainly to access when a mutual coupling due to system geometry or due to ground losses becomes dominant in determining induced effects from lightning in MTLs, which could be an important contribution to the lightning interaction studies for electrified railway systems.

sted, utgiver, år, opplag, sider
2004. Vol. 71, nr 2, s. 186-193
Emneord [en]
lightning; ground impedance; transmission lines; rail transportation power systems; transient analysis
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-62566DOI: 10.1016/j.epsr.2004.02.001ISI: 000223212900011OAI: oai:DiVA.org:kth-62566DiVA, id: diva2:480602
Merknad
QC 20120120Tilgjengelig fra: 2012-01-19 Laget: 2012-01-19 Sist oppdatert: 2017-12-08bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekst

Personposter BETA

Thottappillil, Rajeev

Søk i DiVA

Av forfatter/redaktør
Thottappillil, Rajeev
I samme tidsskrift
Electric power systems research

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 44 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf