Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Characterization of Boreholes: Results from a U-pipe Borehole Heat Exchanger Installation
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Tillämpad termodynamik och kylteknik.ORCID-id: 0000-0002-3490-1777
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Tillämpad termodynamik och kylteknik.ORCID-id: 0000-0002-9902-2087
KTH, Skolan för industriell teknik och management (ITM), Energiteknik, Tillämpad termodynamik och kylteknik.
2008 (engelsk)Inngår i: Proceedings 9th IEA Heat Pump Conference 2008: Conference Proceedings, Zurich, Switzerland: International Energy Agency , 2008, s. 4-19Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Heat exchange with the bedrock for ground source heat pumps is commonly done with the help of U-pipe energy collectors in vertical boreholes. At the moment, there exist many uncertainties about how efficient the heat transfer between the rock and the collector is. For a complete performance analysis of these systems, a 260 m deep water filled borehole is characterized, by measuring the borehole deviation, the ground water flow and the undisturbed ground temperature. Significant attention is devoted to detailed temperature measurements along the borehole depth during operation providing a complete description of the temperature variations in time both for the secondary working fluid and for the ground water. The results show a deviated borehole from the vertical direction without any relevant ground water flow. The undisturbed ground temperature gradient varies from negative to positive at approximately half of the borehole depth. The transient response of the borehole during the heat pump start up is illustrated and it is observed that there does not exist any thermal short circuiting between the down and up-going pipes when the system is in operation.

sted, utgiver, år, opplag, sider
Zurich, Switzerland: International Energy Agency , 2008. s. 4-19
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-73163ISBN: 978-91-85829-81-1 (tryckt)OAI: oai:DiVA.org:kth-73163DiVA, id: diva2:488594
Konferanse
9th International Energy Agency Heat Pump Conference. Zürich, Switzerland. 20 - 22 May 2008
Merknad
QC 20120514Tilgjengelig fra: 2012-02-01 Laget: 2012-02-01 Sist oppdatert: 2012-05-14bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Personposter BETA

Acuña, JoséPalm, Björn

Søk i DiVA

Av forfatter/redaktør
Acuña, JoséPalm, BjörnHill, Peter
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetric

isbn
urn-nbn
Totalt: 1008 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf