Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Study of the dynamics of transcephalic cerebral impedance data during cardio-vascular surgery
KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.ORCID-id: 0000-0002-0928-8501
KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.ORCID-id: 0000-0002-6995-967X
KTH, Skolan för teknik och hälsa (STH), Medicinsk teknik, Medicinska sensorer, signaler och system.
2013 (engelsk)Inngår i: XV International Conference on Electrical Bio-Impedance (ICEBI) & XIV Conference on Electrical Impedance Tomography (EIT), Institute of Physics (IOP), 2013, Vol. 434, nr 1, s. 012045-Konferansepaper, Publicerat paper (Fagfellevurdert)
Abstract [en]

Postoperative neurological deficits are one of the risks associated with cardio vascular surgery, necessitating development of new techniques for cerebral monitoring. In this study an experimental observation regarding the dynamics of transcephalic Electrical Bioimpedance (EBI) in patients undergoing cardiac surgery with and without extracorporeal circulation (ECC) was conducted to investigate the potential use of electrical Bioimpedance for cerebral monitoring in cardio vascular surgery. Tetrapolar transcephalic EBI measurements at single frequency of 50 kHz were recorded prior to and during cardio vascular surgery. The obtained results show that the transcephalic impedance decreases in both groups of patients as operation starts, however slight differences in these two groups were also observed with the cerebral impedance reduction in patients having no ECC being less common and not as pronounced as in the ECC group. Changes in the cerebral impedance were in agreement with changes of haematocrit and temperature. The origin of EBI changes is still unexplained however these results encourage us to continue investigating the application of electrical bioimpedance cerebral monitoring clinically.

sted, utgiver, år, opplag, sider
Institute of Physics (IOP), 2013. Vol. 434, nr 1, s. 012045-
Serie
Journal of Physics: Conference Series, ISSN 1742-6588 ; 434
Emneord [en]
Cardiac surgery, Cerebral monitoring, Electrical bio-impedance, Experimental observation, Extracorporeal circulation, Neurological deficit, Single frequency, Vascular surgery, Cardiovascular surgery, Electric impedance tomography, Electric impedance
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-134475DOI: 10.1088/1742-6596/434/1/012045ISI: 000326512200045Scopus ID: 2-s2.0-84877358321OAI: oai:DiVA.org:kth-134475DiVA, id: diva2:668325
Konferanse
15th International Conference on Electrical Bio-Impedance, ICEBI 2013 and 14th Conference on Electrical Impedance Tomography, EIT 2013; Heilbad Heiligenstadt; Germany; 22 April 2013 through 25 April 2013
Merknad

QC 20131129

Tilgjengelig fra: 2013-11-29 Laget: 2013-11-25 Sist oppdatert: 2013-12-06bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Atefi, Seyed RezaSeoane, Fernando

Søk i DiVA

Av forfatter/redaktør
Atefi, Seyed RezaSeoane, FernandoLindecrantz, Kaj
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 561 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf