Endre søk
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Development and validation of a novel iOS application for measuring arm inclination
KTH, Skolan för teknik och hälsa (STH).
2015 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgave
Abstract [en]

Work in demanding postures is a known risk factor for work-related musculoskeletal disorders (MSDs), specifically work with elevated arms may cause neck/shoulder disorders. Such a disorder is a tragedy for the individual, and costly for society. Technical measurements are more precise in estimating the work exposure, than observation and self-reports, and there is a need for uncomplicated methods for risk assessments. The aim of this project was to develop and validate an iOS application for measuring arm elevation angle.

Such an application was developed, based on the built-in accelerometer and gyroscope of the iPhone/iPod Touch. The application was designed to be self-exploratory. Directly after a measurement, 10th, 50th and 90th percentiles of angular distribution and median angular velocity, and percentage of time above 30°, 60°, and 90° are presented. The focused user group, ergonomists, was consulted during the user interface design phase. Complete angular datasets may be exported via email as text files for further analyses.

The application was validated by comparison to the output of an optical motion capture system for four subjects. The two methods correlated above 0.99, with absolute error below 4.8° in arm flexion and abduction positions. During arm swing movements, the average root-mean-square differences (RMSDs) were 3.7°, 4.6° and 6.5° for slow (0.1 Hz), medium (0.4 Hz) and fast (0.8 Hz) arm swings, respectively. For simulated painting, the mean RMSDs was 5.5°.

Since the accuracy was similar to other tested field research methods, this convenient and “low-cost” application should be useful for ergonomists, for risk assessments or educational use. The plan is to publish this iOS application on Apple Store (Apple Inc.) for free. New user feedback may further improve the user interface.

sted, utgiver, år, opplag, sider
2015. , s. 32
Serie
TRITA-STH ; 2015: 078
Emneord [en]
Accelerometer, gyroscope, physical work exposure, smartphone application
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-173361OAI: oai:DiVA.org:kth-173361DiVA, id: diva2:852824
Eksternt samarbeid
Karolinska Institutet
Fag / kurs
Medical Engineering
Utdanningsprogram
Master of Science - Medical Engineering
Presentation
2015-06-12, 09:00 (engelsk)
Veileder
Examiner
Tilgjengelig fra: 2015-09-22 Laget: 2015-09-10 Sist oppdatert: 2022-06-23bibliografisk kontrollert

Open Access i DiVA

fulltext(1614 kB)1130 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 1614 kBChecksum SHA-512
69156344ec61a6d8c0ff5052fdde915bbad09c674fbb03af92825378408e4244d1a7cc156e8b03d513faf564990b3d1d2970df727378662e8539d80ad1e5aaf1
Type fulltextMimetype application/pdf

Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 1130 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 1956 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf