How to measure renal artery stenosis - a retrospective comparison of morphological measurement approaches in relation to hemodynamic significance
Vise andre og tillknytning
2015 (engelsk)Inngår i: BMC Medical Imaging, ISSN 1471-2342, E-ISSN 1471-2342, Vol. 15, artikkel-id 42Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Background: Although it is well known that renal artery stenosis may cause renovascular hypertension, it is unclear how the degree of stenosis should best be measured in morphological images. The aim of this study was to determine which morphological measures from Computed Tomography Angiography (CTA) and Magnetic Resonance Angiography (MRA) are best in predicting whether a renal artery stenosis is hemodynamically significant or not. Methods: Forty-seven patients with hypertension and a clinical suspicion of renovascular hypertension were examined with CTA, MRA, captopril-enhanced renography (CER) and captopril test (Ctest). CTA and MRA images of the renal arteries were analyzed by two readers using interactive vessel segmentation software. The measures included minimum diameter, minimum area, diameter reduction and area reduction. In addition, two radiologists visually judged the diameter reduction without automated segmentation. The results were then compared using limits of agreement and intra-class correlation, and correlated with the results from CER combined with Ctest (which were used as standard of reference) using receiver operating characteristics (ROC) analysis. Results: A total of 68 kidneys had all three investigations (CTA, MRA and CER + Ctest), where 11 kidneys (16.2 %) got a positive result on the CER + Ctest. The greatest area under ROC curve (AUROC) was found for the area reduction on MRA, with a value of 0.91 (95 % confidence interval 0.82-0.99), excluding accessory renal arteries. As comparison, the AUROC for the radiologists' visual assessments on CTA and MRA were 0.90 (0.82-0.98) and 0.91 (0.83-0.99) respectively. None of the differences were statistically significant. Conclusions: No significant differences were found between the morphological measures in their ability to predict hemodynamically significant stenosis, but a tendency of MRA having higher AUROC than CTA. There was no significant difference between measurements made by the radiologists and measurements made with fuzzy connectedness segmentation. Further studies are required to definitely identify the optimal measurement approach.

sted, utgiver, år, opplag, sider
BioMed Central, 2015. Vol. 15, artikkel-id 42
Emneord [en]
Renal artery stenosis, Computed tomography angiography, Magnetic resonance angiography, Renography, Fuzzy connectedness segmentation, Vessel diameter, Cross-sectional area
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-176337DOI: 10.1186/s12880-015-0086-8ISI: 000362535400001PubMedID: 26459634Scopus ID: 2-s2.0-84959196474OAI: oai:DiVA.org:kth-176337DiVA, id: diva2:867035
Merknad

QC 20151104

Tilgjengelig fra: 2015-11-04 Laget: 2015-11-03 Sist oppdatert: 2017-12-01bibliografisk kontrollert

Open Access i DiVA

Andersson 2015 renal artery stenosis(2977 kB)80 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 2977 kBChecksum SHA-512
db2cf22448882c2d7026503bf9b32ac47cd0333b08d7a2778f6603c544875c4c40a7ccf3a1d06fb4b7601ae736c5ef7264e0204f7dd46925639d6c9584d169cf
Type fulltextMimetype application/pdf

Andre lenker

Forlagets fulltekstPubMedScopus

Personposter BETA

Wang, ChunliangSmedby, Örjan

Søk i DiVA

Av forfatter/redaktør
Wang, ChunliangSmedby, Örjan
I samme tidsskrift
BMC Medical Imaging

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 80 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

doi
pubmed
urn-nbn

Altmetric

doi
pubmed
urn-nbn
Totalt: 180 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf