Load curtailment minimization by optimal placements of SVC/STATCOM
KTH, Skolan för elektro- och systemteknik (EES), Elkraftteknik.ORCID-id: 0000-0002-8189-2420
2015 (engelsk)Inngår i: International Transactions on Electrical Energy Systems, E-ISSN 2050-7038, Vol. 25, nr 11, s. 2769-2780Artikkel i tidsskrift (Fagfellevurdert) Published
Resurstyp
Text
Abstract [en]

In this paper, a new sensitivity-based methodology has been proposed for optimal placement of a static VAr compensator (SVC)/static synchronous compensator (STATCOM) to minimize load curtailment that is required to ensure system security, integrity and reliability after undesirable changes occur in the system. SVC/STATCOM has a significant impact on control of reactive power and thereby system bus voltages. This motivated to develop an appropriate approach to find their optimal location in order to accomplish the above said objective. The suggested sensitivity factors have been defined as the rate of change in load curtailment with respect to the change in SVC/STATCOM control settings. To investigate the effectiveness of the proposed methodology an optimal power flow problem has been formulated with an objective to minimize the load curtailment and is tested on IEEE 14-bus and practical 75-bus Indian systems. It is observed from the obtained results that the required load curtailment drastically reduced with the placement of SVC/STATCOM, along with improvement in system voltage profile at various operating conditions. This methodology can be used to limit the amount of load curtailment, thereby reducing lost revenue, outage cost, customer's service interruption and possibly civil unrest in some areas. 

sted, utgiver, år, opplag, sider
Wiley-Blackwell, 2015. Vol. 25, nr 11, s. 2769-2780
Emneord [en]
FACTS controller, load curtailment, optimal placement, sensitivity factor, SVC, STATCOM
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-181397DOI: 10.1002/etep.1990ISI: 000367675600012Scopus ID: 2-s2.0-84954434211OAI: oai:DiVA.org:kth-181397DiVA, id: diva2:899406
Merknad

QC 20160201

Tilgjengelig fra: 2016-02-01 Laget: 2016-02-01 Sist oppdatert: 2017-11-30bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Söder, Lennart

Søk i DiVA

Av forfatter/redaktør
Söder, Lennart
Av organisasjonen
I samme tidsskrift
International Transactions on Electrical Energy Systems

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 82 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf