Welding of dissimilar metals in different welding positions
KTH, Skolan för industriell teknik och management (ITM), Materialvetenskap.
2016 (engelsk)Independent thesis Advanced level (degree of Master (Two Years)), 20 poäng / 30 hpOppgave
Abstract [en]

The three boiling water reactors (BWR) in Oskarshamn produce about 10 % of the electrical power in Sweden. The combination of intense radiation fluxes and high temperatures in nuclear reactors creates an extraordinary environment. Therefore, a number of material challenges arise at a nuclear power plant that needs to be solved in order to maintain the nuclear power production, safety and reliability.

Dissimilar metal welds can be found at a lot of places in nuclear power plants and due to reparations or replacement some dissimilar metal welds need to be welded on site. The technical regulations for the Swedish nuclear power plants specifies that welding of dissimilar joints shall be made with gap of at least 1.5 mm and in horizontal position. Welding a dissimilar joint on site makes it difficult to follow the technical regulations, therefore, the aim with this study is to determine if different welding positions of dissimilar metal welds affect the structure and composition of the weld metal in a negative way and to investigate the importance of a gap in the root.

In this study six samples were welded in three different welding positions, horizontal, vertical and reversed vertical with or without a gap of 1.5 mm in the root. The samples were evaluated by non-destructive testing, optical microscopy, chemical analysis, tensile testing, bend testing and hardness measurements.

The results shows that two of the samples welded without gap failed the transverse root bend test, the same samples did also have high hardness values in the root bead.

The conclusions are that the welding position, horizontal, vertical or reversed vertical does not affect the weld negative in a noticeable way. However, the gap and a good dilution with the filler metal are important.

sted, utgiver, år, opplag, sider
2016.
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-184241OAI: oai:DiVA.org:kth-184241DiVA, id: diva2:915802
Eksternt samarbeid
E-ON OKG AB
Fag / kurs
Materials and Process Design
Utdanningsprogram
Master of Science - Materials Science and Engineering
Veileder
Examiner
Tilgjengelig fra: 2016-05-17 Laget: 2016-03-31 Sist oppdatert: 2016-05-17bibliografisk kontrollert

Open Access i DiVA

fulltext(7491 kB)1427 nedlastinger
Filinformasjon
Fil FULLTEXT01.pdfFilstørrelse 7491 kBChecksum SHA-512
02cc3b08f9dd6ec8eb59e2efce9e71589deb9295ee1bceef9ab7683aa2b6c93949e46cfa50c8b37835293c379f92dab70433d88d5ece5e696fcb326f923841fa
Type fulltextMimetype application/pdf

Søk i DiVA

Av forfatter/redaktør
Bäck, Mimmi
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar
Totalt: 1427 nedlastinger
Antall nedlastinger er summen av alle nedlastinger av alle fulltekster. Det kan for eksempel være tidligere versjoner som er ikke lenger tilgjengelige

urn-nbn

Altmetric

urn-nbn
Totalt: 785 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf