On the assessment of bridging vein rupture associated acute subdural hematoma through finite element analysis
Visa övriga samt affilieringar
2017 (Engelska)Ingår i: Computer Methods in Biomechanics and Biomedical Engineering, ISSN 1025-5842, E-ISSN 1476-8259, Vol. 20, nr 5, s. 530-539Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Acute subdural hematoma (ASDH) is a type of intracranial haemorrhage following head impact, with high mortality rates. Bridging vein (BV) rupture is a major cause of ASDH, which is why a biofidelic representation of BVs in finite element (FE) head models is essential for the successful prediction of ASDH. We investigated the mechanical behavior of BVs in the KTH FE head model. First, a sensitivity study quantified the effect of loading conditions and mechanical properties on BV strain. It was found that the peak rotational velocity and acceleration and pulse duration have a pronounced effect on the BV strains. Both Young's modulus and diameter are also negatively correlated with the BV strains. A normalized multiple linear regression model using Young's modulus, outer diameter and peak rotational velocity to predict the BV strain yields an adjusted -value of 0.81. Secondly, cadaver head impact experiments were simulated with varying sets of mechanical properties, upon which the amount of successful BV rupture predictions was evaluated. The success rate fluctuated between 67 and 75%. To further increase the predictive capability of FE head models w.r.t. BV rupture, future work should be directed towards improvement of the BV representation, both geometrically and mechanically.

Ort, förlag, år, upplaga, sidor
Taylor & Francis, 2017. Vol. 20, nr 5, s. 530-539
Nyckelord [en]
Bridging veins, acute subdural hematoma, mechanical properties, finite element modelling, head impact
Nationell ämneskategori
Teknisk mekanik
Identifikatorer
URN: urn:nbn:se:kth:diva-205436DOI: 10.1080/10255842.2016.1255942ISI: 000395351500008PubMedID: 27838925Scopus ID: 2-s2.0-84994896188OAI: oai:DiVA.org:kth-205436DiVA, id: diva2:1097190
Anmärkning

QC 20170522

Tillgänglig från: 2017-05-22 Skapad: 2017-05-22 Senast uppdaterad: 2017-05-22Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextPubMedScopus

Personposter BETA

Kleiven, Svein

Sök vidare i DiVA

Av författaren/redaktören
Kleiven, Svein
Av organisationen
Neuronik
I samma tidskrift
Computer Methods in Biomechanics and Biomedical Engineering
Teknisk mekanik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
pubmed
urn-nbn

Altmetricpoäng

doi
pubmed
urn-nbn
Totalt: 192 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf