Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Beam test measurements of Low Gain Avalanche Detector single pads and arrays for the ATLAS High Granularity Timing Detector
Univ Paris Saclay, Univ Paris Sud, CNRS IN2P3, LAL, Orsay, France..
Univ Iowa, Iowa City, IA USA..
UPMC, Lab Phys Nucl & Hautes Energies, Paris, France.;Univ Paris Diderot, Paris, France.;CNRS IN2P3, Paris, France..
UPMC, Lab Phys Nucl & Hautes Energies, Paris, France.;Univ Paris Diderot, Paris, France.;CNRS IN2P3, Paris, France..
Visa övriga samt affilieringar
2018 (Engelska)Ingår i: Journal of Instrumentation, ISSN 1748-0221, E-ISSN 1748-0221, Vol. 13, artikel-id P06017Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

For the high luminosity upgrade of the LHC at CERN, ATLAS is considering the addition of a High Granularity Timing Detector (HGTD) in front of the end cap and forward calorimeters at vertical bar z vertical bar = 3:5 m and covering the region 2:4 < vertical bar eta vertical bar < 4 to help reducing the effect of pile-up. The chosen sensors are arrays of 50 mu m thin Low Gain Avalanche Detectors (LGAD). This paper presents results on single LGAD sensors with a surface area of 1.3 x 1.3 mm(2) and arrays with 2 x 2 pads with a surface area of 2 x 2 mm(2) or 3 x 3 mm(2) each and different implant doses of the p(+) multiplication layer. They are obtained from data collected during a beam test campaign in autumn 2016 with a pion beam of 120 GeV energy at the CERN SPS. In addition to several quantities measured inclusively for each pad, the gain, efficiency and time resolution have been estimated as a function of the position of the incident particle inside the pad by using a beam telescope with a position resolution of few mu m. Different methods to measure the time resolution are compared, yielding consistent results. The sensors with a surface area of 1.3 x 1.3 mm(2) have a time resolution of about 40 ps for a gain of 20 and of about 27 ps for a gain of 50 and fulfil the HGTD requirements. Larger sensors have, as expected, a degraded time resolution. All sensors show very good efficiency and time resolution uniformity.

Ort, förlag, år, upplaga, sidor
Institute of Physics (IOP), 2018. Vol. 13, artikel-id P06017
Nyckelord [en]
Si microstrip and pad detectors, Solid state detectors, Timing detectors
Nationell ämneskategori
Annan teknik
Identifikatorer
URN: urn:nbn:se:kth:diva-240238DOI: 10.1088/1748-0221/13/06/P06017ISI: 000436180900001Scopus ID: 2-s2.0-85049997990OAI: oai:DiVA.org:kth-240238DiVA, id: diva2:1272136
Anmärkning

QC 20181218

Tillgänglig från: 2018-12-18 Skapad: 2018-12-18 Senast uppdaterad: 2018-12-18Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Kastanas, Konstatinos A.

Sök vidare i DiVA

Av författaren/redaktören
Kastanas, Konstatinos A.
Av organisationen
Fysik
I samma tidskrift
Journal of Instrumentation
Annan teknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 38 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf