Design of Filter-Based Stabilizing Control for PLL-Synchronized Converters
Southeast Univ, Sch Elect Engn, Nanjing 210096, Peoples R China..
Southeast Univ, Sch Elect Engn, Nanjing 210096, Peoples R China..
Southeast Univ, Sch Elect Engn, Nanjing 210096, Peoples R China..
Univ Nottingham Ningbo China, Ningbo 315104, Peoples R China..
Visa övriga samt affilieringar
2024 (Engelska)Ingår i: IEEE Transactions on Industrial Electronics, ISSN 0278-0046, E-ISSN 1557-9948, s. 1-12Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The phase-locked loop (PLL) has an important effect on the system stability of grid-connected converters in weak grids. In the literature, parameter tuning methods and stabilizing control strategies have been proposed to deal with this problem. However, most of them target at tuning parameters of PLL or mitigating the negative damping as well as the phase lag introduced by the PLL, while the interactions between the PLL and the current control and the cross coupling effects are still not fully explored in the design procedure of stabilizing control. To address this issue, this article extends the study of the interaction between the PLL and the current control using a multiple-input multiple-output (MIMO) model, and then proposes a design criterion of the stabilizing control using design-oriented analysis from the perspective of MIMO impedance model. A category of stabilizing control schemes that uses different types of biquad filters is proposed following the criterion, which not only improves system stability but also removes the coupling between the PLL and the current control according to the sensitivity analysis. Hardware-in-the-loop and experimental results are provided to verify the effectiveness of the proposed control schemes.

Ort, förlag, år, upplaga, sidor
Institute of Electrical and Electronics Engineers (IEEE) , 2024. s. 1-12
Nyckelord [en]
Control design, phase-locked loop (PLL)-synchronized converter, PLL, sensitivity analysis, stability
Nationell ämneskategori
Annan elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:kth:diva-345578DOI: 10.1109/TIE.2024.3374361ISI: 001193677300001Scopus ID: 2-s2.0-85188943181OAI: oai:DiVA.org:kth-345578DiVA, id: diva2:1851558
Anmärkning

QC 20240415

Tillgänglig från: 2024-04-15 Skapad: 2024-04-15 Senast uppdaterad: 2024-04-15Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Person

Wang, Xiongfei

Sök vidare i DiVA

Av författaren/redaktören
Wang, Xiongfei
Av organisationen
Elkraftteknik
I samma tidskrift
IEEE Transactions on Industrial Electronics
Annan elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 12 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf