Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Standard orientation of the pelvis: Validation on a model and ten patients
Karolinska Institutet, Department of Clinical Science, Intervention and Technology, Division of Radiology.
Karolinska Institutet, Department of Clinical Science, Intervention and Technology, Division of Radiology.
Karolinska Institute, Department of Molecular Medicine and Surgery.
Karolinska Institute, Department of Molecular Medicine and Surgery.
Visa övriga samt affilieringar
2005 (Engelska)Ingår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 46, nr 1, s. 74-82Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose: To validate an image post-processing method for re-orienting the pelvis in CT volumes to a standardized orientation in a model and in 10 patients. Material and Methods: Twenty-four CT volumes of a pelvic model and 10 pairs of postoperative total hip arthroplasty (THA) patient CT scans were rotated to a defined pelvic standard orientation and the rotation was recorded. For precision, a test-retest procedure was used. For accuracy, three exactly represented coordinate points were used. For clinical application, the standard orientation was used for calculating the direction of acetabular cup migration from a previous model study. Results: Precision of pelvic standard orientation, calculated as maximal directional error, was better than 1degrees in the model study and better than 1.5degrees in the patient study. Accuracy, expressed as angle between ideal and measured coordinate axes, was 0.1degrees for x, y, z axes. No measurable systematic errors were found. When applied to acetabular cup migration in the model, standardization of pelvic orientation had no significant effect on the measurements. Conclusion: Reorienting the pelvis during image post-processing was shown to be accurate. It enables measurements relative to the pelvis and minimizes the dependency of patient positioning.

Ort, förlag, år, upplaga, sidor
London, UK: Informa Healthcare, 2005. Vol. 46, nr 1, s. 74-82
Nyckelord [en]
CT, hip, arthroplasty, total hip-arthroplasty, acetabular component migration, semiautomated program, computed-tomography, ct, fusion, cup, anteversion, alignment
Nationell ämneskategori
Radiologi och bildbehandling
Forskningsämne
SRA - Informations- och kommunikationsteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-14561DOI: 10.1080/02841850510016063ISI: 000227276400012OAI: oai:DiVA.org:kth-14561DiVA: diva2:332602
Anmärkning
QC 20100525Tillgänglig från: 2010-08-05 Skapad: 2010-08-05 Senast uppdaterad: 2017-12-12Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Maguire Jr., Gerald Q.

Sök vidare i DiVA

Av författaren/redaktören
Maguire Jr., Gerald Q.Svensson, Lars E.
Av organisationen
Kommunikationssystem, CoSMatematik (Inst.)
I samma tidskrift
Acta Radiologica
Radiologi och bildbehandling

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 142 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf