A procedure to simulate coronary artery bypass graft surgery
KTH, Skolan för teknikvetenskap (SCI), Hållfasthetslära (Inst.), Biomekanik.
2007 (Engelska)Ingår i: Medical and Biological Engineering and Computing, ISSN 0140-0118, E-ISSN 1741-0444, Vol. 45, nr 9, s. 819-827Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

In coronary artery bypass graft (CABG) surgery the involved tissues are overstretched, which may lead to intimal hyperplasia and graft failure. We propose a computational methodology for the simulation of traditional CABG surgery, and analyze the effect of two clinically relevant parameters on the artery and graft responses, i.e., incision length and insertion angle for a given graft diameter. The computational structural analyses are based on actual three-dimensional vessel dimensions of a human coronary artery and a human saphenous vein. The analyses consider the structure of the end-to-side anastomosis, the residual stresses and the typical anisotropic and nonlinear vessel behaviors. The coronary artery is modeled as a three-layer thick-walled tube. The finite element method is employed to predict deformation and stress distribution at various stages of CABG surgery. Small variations of the arterial incision have relatively big effects on the size of the arterial opening, which depends solely on the residual stress state. The incision length has a critical influence on the graft shape and the stress in the graft wall. Stresses at the heel region are higher than those at the toe region. The changes in the mechanical environment are severe along all transitions between the venous tissue and the host artery. Particular stress concentrations occur at the incision ends. The proposed computational methodology may be useful in designing a coronary anastomotic device for reducing surgical trauma. It may improve the quantitative knowledge of vessel diseases and serve as a tool for virtual planning of vascular surgery.

Ort, förlag, år, upplaga, sidor
2007. Vol. 45, nr 9, s. 819-827
Nyckelord [en]
CABG, end-to-side anastomosis, finite element method, intimal hyperplasia, solid mechanics, human saphenous-vein, anastomotic intimal hyperplasia, to-side anastomosis, mechanical-properties, wall mechanics, models, injury
Identifikatorer
URN: urn:nbn:se:kth:diva-17053DOI: 10.1007/s11517-007-0201-2ISI: 000250299400002Scopus ID: 2-s2.0-34548687719OAI: oai:DiVA.org:kth-17053DiVA, id: diva2:335096
Anmärkning
QC 20100525Tillgänglig från: 2010-08-05 Skapad: 2010-08-05 Senast uppdaterad: 2017-12-12Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Holzapfel, Gerhard A.
Av organisationen
Biomekanik
I samma tidskrift
Medical and Biological Engineering and Computing

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 71 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf