In Vitro Angioplasty of Atherosclerotic Human Femoral Arteries: Analysis of the Geometrical Changes in the Individual Tissues Using MRI and Image Processing
Visa övriga samt affilieringar
2010 (Engelska)Ingår i: Annals of Biomedical Engineering, ISSN 0090-6964, E-ISSN 1573-9686, Vol. 38, nr 4, s. 1276-1287Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Existing atherosclerotic plaque imaging techniques such as intravascular ultrasound, multidetector computed tomography, optical coherence tomography, and high-resolution magnetic resonance imaging (hrMRI) require computerized methods to separate and analyze the plaque morphology. In this work, we perform in vitro balloon angioplasty experiments with 10 human femoral arteries using hrMRI and image processing. The vessel segments contain low-grade to high-grade lesions with very different plaque compositions. The experiments are designed to mimic the in vivo situation. We use a semi-automatic image processing tool to extract the three-dimensional (3D) geometries of the tissue components at four characteristic stages of the angioplasty procedure. The obtained geometries are then used to determine geometrical and mechanical indices in order to characterize, classify, and analyze the atherosclerotic plaques by their specific geometrical changes. During inflation, three vessels ruptured via helical crack propagation. The adventitia, media, and intima did not preserve their area/volume during inflation; the area changes of the lipid pool during inflation were significant. The characterization of changes in individual 3D tissue geometries, together with tissue-specific mechanical properties, may serve as a basis for refined finite element (FE) modeling, which is key to better understand stress evolution in various atherosclerotic plaque configurations.

Ort, förlag, år, upplaga, sidor
2010. Vol. 38, nr 4, s. 1276-1287
Nyckelord [en]
3D reconstruction, Atherosclerotic plaque, Balloon angioplasty, Magnetic resonance imaging, Model-based segmentation, optical coherence tomography, intravascular ultrasound, magnetic-resonance, mechanical-properties, quantitative-analysis, 3-d, reconstruction, plaque, wall, components, stiffness
Nationell ämneskategori
Medicin och hälsovetenskap
Identifikatorer
URN: urn:nbn:se:kth:diva-19346DOI: 10.1007/s10439-010-9954-0ISI: 000276046600002Scopus ID: 2-s2.0-77952009689OAI: oai:DiVA.org:kth-19346DiVA, id: diva2:337393
Anmärkning
QC 20100525Tillgänglig från: 2010-08-05 Skapad: 2010-08-05 Senast uppdaterad: 2017-12-12Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Holzapfel, Gerhard A.
Av organisationen
Biomekanik
I samma tidskrift
Annals of Biomedical Engineering
Medicin och hälsovetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 356 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf