Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Acetabular component migration in total hip arthroplasty using CT and a semiautomated program for volume merging
Karolinska Hospital, Department of Radiology.
Karolinska Hospital, Department of Radiology.
Karolinska Hosp, Dept Orthopaed.
New York University, Department of Radiology. (Nuclear Medicine)
Visa övriga samt affilieringar
2002 (Engelska)Ingår i: Acta Radiologica, ISSN 0284-1851, E-ISSN 1600-0455, Vol. 43, nr 5, s. 517-527Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Purpose: To develop a non-invasive method for detection of acetabular cup migration after total hip arthroplasty (THA) with a higher degree of accuracy than routine plain radiography. Material and Methods: Two CT examinations, 10 min apart, were obtained from each of 10 patients that had undergone THA. Using an in-house developed semiautomated program for volume merging, the pelves in the two examinations were fused and the acetabular cup was visually and numerically evaluated to test the method's accuracy in detecting migration. Results: In the visual evaluation of the best match a 1-mm translation of the cup was detectable. The numerical evaluation, comparing landmarks placed in the images of the acetabular cup and the head of the femur component in the two examinations, showed the mean difference in orientation of acetabular axes to be 2.5degrees, the mean distance between centre of cup face to be 2.5 mm and the mean distance between centre of the head of the prosthetic femoral component to be 1 mm. Conclusion: This method has a significantly higher accuracy than routine plain radiography in detecting acetabular cup migration and could be used in clinical practice. It gives both a visual and a numerical correlate to migration.

Ort, förlag, år, upplaga, sidor
2002. Vol. 43, nr 5, s. 517-527
Nyckelord [en]
hip prosthesis, volume merging, CT, experimental, medical image registration, fusion
Nationell ämneskategori
Radiologi och bildbehandling Ortopedi
Forskningsämne
SRA - Informations- och kommunikationsteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-22071DOI: 10.1034/j.1600-0455.2002.430513.xISI: 000179450300013OAI: oai:DiVA.org:kth-22071DiVA, id: diva2:340769
Anmärkning
QC 20100525 NR 20140804Tillgänglig från: 2010-08-10 Skapad: 2010-08-10 Senast uppdaterad: 2018-01-12Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Personposter BETA

Maguire Jr., Gerald Q.

Sök vidare i DiVA

Av författaren/redaktören
Maguire Jr., Gerald Q.Svensson, Lars E.
Av organisationen
Mikroelektronik och informationsteknik, IMITMatematik (Inst.)
I samma tidskrift
Acta Radiologica
Radiologi och bildbehandlingOrtopedi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 174 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf