A new device for controlled eccentric overloading in training and rehabilitation
Karolinska Institute.
Swedish School of Sports and Helath Sciences. (Biomechanics and Motor control)
Swedish School of Sports and Health Sciences.
2005 (Engelska)Ingår i: European Journal of Applied Physiology, ISSN 1439-6319, E-ISSN 1439-6327, Vol. 94, nr 1-2, s. 168-174Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The aim of this work was to evaluate a device that allows for eccentric overload to be applied under controlled and safe conditions and it is applicable in exercises commonly used in training and rehabilitation. The machine contains a barbell, which is lowered and raised by a motor, following a predetermined velocity profile. It is capable of handling heavy loads (> 500 kg) and is instrumented with a sensor to measure the velocity of the barbell and two scales to measure the vertical component of the ground reaction force. The velocity recordings of the built-in displacement sensor were found to correspond well with those obtained using a motion-capture system. Applying known weights on each scale demonstrated linearity with respect to magnitude and independence regarding location of application. The velocity of the barbell was found to be dependent on the load on the barbell and on the resisting force produced by the individual training in the machine. The combined man-machine reliability was tested using a group of habitually active males (n = 13, 2855 years) performing squats. Peak voluntary resisting force and position at peak resistance were recorded on two occasions, showing no significant differences and a coefficient of variation of 9% and 22%, respectively. Preliminary observations from training in the machine have been positive both for increasing performance in top athletes and for causing pain relief in patients with diffuse knee problems. The possibility of feedback of the force under each foot makes individual dosage of training load possible, which is valuable, e.g. in rehabilitation of a unilateral injury.

Ort, förlag, år, upplaga, sidor
2005. Vol. 94, nr 1-2, s. 168-174
Nationell ämneskategori
Idrottsvetenskap
Identifikatorer
URN: urn:nbn:se:kth:diva-83691DOI: 10.1007/s00421-004-1298-8ISI: 000229116400022OAI: oai:DiVA.org:kth-83691DiVA, id: diva2:498911
Anmärkning
QC 20120221Tillgänglig från: 2012-02-12 Skapad: 2012-02-12 Senast uppdaterad: 2017-12-07Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltext

Sök vidare i DiVA

Av författaren/redaktören
Halvorsen, Kjartan
I samma tidskrift
European Journal of Applied Physiology
Idrottsvetenskap

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 58 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf