Inter-laboratory validation of bioaccessibility testing for metals
Visa övriga samt affilieringar
2014 (Engelska)Ingår i: Regulatory toxicology and pharmacology, ISSN 0273-2300, E-ISSN 1096-0295, Vol. 70, nr 1, s. 170-181Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

Bioelution assays are fast, simple alternatives to in vivo testing. In this study, the intra- and inter-laboratory variability in bioaccessibility data generated by bioelution tests were evaluated in synthetic fluids relevant to oral, inhalation, and dermal exposure. Using one defined protocol, five laboratories measured metal release from cobalt oxide, cobalt powder, copper concentrate, Inconel alloy, leaded brass alloy, and nickel sulfate hexahydrate. Standard deviations of repeatability (S-r) and reproducibility (S-R) were used to evaluate the intra- and inter-laboratory variability, respectively. Examination of the s(R):s(r) ratios demonstrated that, while gastric and lysosomal fluids had reasonably good reproducibility, other fluids did not show as good concordance between laboratories. Relative standard deviation (RSD) analysis showed more favorable reproducibility outcomes for some data sets; overall results varied more between- than within-laboratories. RSD analysis of s(r) showed good within-laboratory variability for all conditions except some metals in interstitial fluid. In general, these findings indicate that absolute bioaccessibility results in some biological fluids may vary between different laboratories. However, for most applications, measures of relative bioaccessibility are needed, diminishing the requirement for high inter-laboratory reproducibility in absolute metal releases. The inter-laboratory exercise suggests that the degrees of freedom within the protocol need to be addressed.

Ort, förlag, år, upplaga, sidor
2014. Vol. 70, nr 1, s. 170-181
Nyckelord [en]
Metals, Alloys, UVCBs, Classification, Bioelution, Bioaccessibility, Read-across, Inter-laboratory validation
Nationell ämneskategori
Farmakologi och toxikologi
Identifikatorer
URN: urn:nbn:se:kth:diva-154753DOI: 10.1016/j.yrtph.2014.06.021ISI: 000342482200018Scopus ID: 2-s2.0-84904408802OAI: oai:DiVA.org:kth-154753DiVA, id: diva2:763118
Anmärkning

QC 20141113

Tillgänglig från: 2014-11-13 Skapad: 2014-10-27 Senast uppdaterad: 2018-01-11Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Personposter BETA

Herting, GunillaWallinder, Inger Odnevall

Sök vidare i DiVA

Av författaren/redaktören
Herting, GunillaWallinder, Inger Odnevall
Av organisationen
Yt- och korrosionsvetenskap
I samma tidskrift
Regulatory toxicology and pharmacology
Farmakologi och toxikologi

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetricpoäng

doi
urn-nbn
Totalt: 98 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf