Ändra sökning
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf
Microstructural effects on the wear resistance of CO-CR implant alloys
KTH, Skolan för industriell teknik och management (ITM), Materialvetenskap.
Visa övriga samt affilieringar
2006 (Engelska)Ingår i: Proceedings of the 8th Biennial Conference on Engineering Systems Design and Analysis, 2006, s. -951Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Modem metal-on-metal articulation have been proposed to reduce the incidence of osteolysis due to polyethylene particles debris, as a late complication. The tribology of large metal-on-metal articulations allows theoretical advantages with respect to other configurations, especially for the lubrication regime. This study was aimed to compare the wear performances of different diameters of clinically available acetabular metallic components manufactured in a cast cobalt-chrome alloy. To evaluate the influence of the material properties of wear and microstructure, metal-on-metal components were tested in a hip joint simulator for five million cycles with bovine calf serum as lubricant. In particular, three different configurations of metal-on-metal components (28-mm, 36-mm, 54-mm) were tested. After the test all specimens were examined with optical and electronic scanning microscope. A statistical difference were observed among the three groups tested in the run-in and steady-state wear rates, favoring the larger femoral heads. The results of this study indicate that the 54-mm diameter femoral heads prove a better wear behavior than the smaller configurations.

Ort, förlag, år, upplaga, sidor
2006. s. -951
Serie
Proceedings of 8th Biennial ASME Conference on Engineering Systems Design and Analysis, ESDA2006 ; 2006
Nyckelord [en]
Bovine calf serum, Grain size, Hip simulator, Metallic hip prostheses, Microstructure, Acetabular metallic components, Cobalt-chrome alloy, Femoral heads, Metal articulation, Osteolysis, Debris, Grain size and shape, Lubrication, Polyethylenes, Scanning electron microscopy, Wear resistance, Cobalt alloys
Nationell ämneskategori
Metallurgi och metalliska material
Identifikatorer
URN: urn:nbn:se:kth:diva-155867ISI: 000249558200107Scopus ID: 2-s2.0-33845737480ISBN: 0791837793 (tryckt)ISBN: 9780791837795 (tryckt)OAI: oai:DiVA.org:kth-155867DiVA, id: diva2:764036
Konferens
8th Biennial ASME Conference on Engineering Systems Design and Analysis, ESDA2006, 4 July 2006 through 7 July 2006, Torino
Anmärkning

QC 20141118

Tillgänglig från: 2014-11-18 Skapad: 2014-11-13 Senast uppdaterad: 2014-11-18Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Scopus

Sök vidare i DiVA

Av författaren/redaktören
Jedenmalm, Anneli
Av organisationen
Materialvetenskap
Metallurgi och metalliska material

Sök vidare utanför DiVA

GoogleGoogle Scholar

isbn
urn-nbn

Altmetricpoäng

isbn
urn-nbn
Totalt: 605 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf