The benefit method: Fitting hearing aids in noise
KTH. (BFM Support AB)
KTH, Skolan för datavetenskap och kommunikation (CSC), Tal, musik och hörsel, TMH.
KTH. (BFM Support AB)
Visa övriga samt affilieringar
2005 (Engelska)Ingår i: Noise and Health, ISSN 1463-1741, Vol. 7, nr 29, s. 12-23Artikel i tidskrift (Refereegranskat) Published
Abstract [en]

The most common complaint among individuals with hearing impairment is the inability to follow a conversation when several people are talking simultaneously, a noisy listening situation which is completely different from the quiet surrounding of the conventional pure tone audiometry used as basis for the hearing aid settings. The purpose of this report was to present important characteristics of the BeneFit Method (BFM), a procedure that fits the hearing aid under simulated conditions of competing speech and also a clinical pilot evaluation study comparing the BFM to the NAL-R recommendations and also to the Logic procedure, a GN resound proprietary fitting algorithm representing a modern digital hearing aid fitting procedure. Speech recognition scores in noise (SRSN) using monosyllabic words presented under different background noise levels were evaluated on 21 randomly selected subjects with hearing impairment. The subjects were fitted with the same type of hearing aid Danalogic 163D according to the BFM procedure as well as the logic procedure, the latter developed and recommended by the manufacturer. A comparison of the SRSN when using the subjects' current hearing aid fitted according to the NAL-R procedure was also made. Only the BFM procedure provided a significant SRSN improvement compared to the unaided condition (P<0.01) in a signal/speech-noise level of 75/65 dB corresponding to a normal cocktail party condition. Moreover, patients performed significantly higher SRSN when fitted according to the BFM, than when fitted according the Logic or NAL-R procedures. The BFM procedure, which is based on individual and functional detection of hearing thresholds in noise levels corresponding to a cocktail party condition, can improve SRSN significantly. Hearing aids should be fitted under conditions similar to those when the hearing disability is perceived the most, i.e., in an environment with background noise.

Ort, förlag, år, upplaga, sidor
2005. Vol. 7, nr 29, s. 12-23
Nyckelord [en]
Benefit, Hearing aid fittings, Hearing loss, Noise, aged, algorithm, article, auditory threshold, clinical article, controlled study, female, hearing aid, human, intermethod comparison, male, pilot study, random sample, scoring system, signal noise ratio, simulation, speech, speech discrimination, technique, test retest reliability, Aged, 80 and over, Audiometry, Pure-Tone, Audiometry, Speech, Denmark, Equipment Design, Hearing Aids, Humans, Perceptual Masking, Pilot Projects, Prosthesis Fitting, Reproducibility of Results, Speech Perception
Nationell ämneskategori
Övrig annan teknik
Identifikatorer
URN: urn:nbn:se:kth:diva-157105Scopus ID: 2-s2.0-34250717045OAI: oai:DiVA.org:kth-157105DiVA, id: diva2:771064
Anmärkning

QC 20141212

Tillgänglig från: 2014-12-12 Skapad: 2014-12-05 Senast uppdaterad: 2016-12-21Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Scopus

Sök vidare i DiVA

Av författaren/redaktören
Svärd, I.Spens, Karl-ErikBäck, L.
Av organisationen
KTHTal, musik och hörsel, TMH
Övrig annan teknik

Sök vidare utanför DiVA

GoogleGoogle Scholar

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 70 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf