Geometric Misalignment Calibration and Detector Lag Effect Artifact Correction in a Cone-Beam Flat Panel micro-CT System for Small Animal Imaging
KTH, Skolan för teknik och hälsa (STH).
2015 (Engelska)Självständigt arbete på avancerad nivå (masterexamen), 20 poäng / 30 hpStudentuppsats (Examensarbete)
Abstract [en]

The cone-beam flat panel micro-CT is a high definition imaging system. It acquires projections of an object or animal to reconstruct a 3D image of its internal structure. The device is basically composed by a radiation tube and a detector panel, which are fixed to a gantry that rotates all around the test subject. The micro-CT system is affected by several imperfections and problems, that might lead to serious artifacts that deteriorate the quality of the reconstructed image. In particular, two issues have been discussed in the present work: the source-panel geometric misalignment and the detector lag effect. The first problem concerns the consequences of systems where the different elements are not perfectly aligned to each other. The second issue regards the residual signal, left in the detector's sensor after a projection acquisition, which affects the following frames with ghost images. Both these arguments have been investigated to describe their characteristics and behaviour in a typical acquisition protocol. Then two correction methods have been presented and tested on a real micro-CT device to verify their effectiveness in the artifacts compensation. In the end, a comparison between images before and after the corrections is provided and future prospects are discussed.

Ort, förlag, år, upplaga, sidor
2015. , s. 118
Serie
TRITA-STH ; 2015:112
Nyckelord [en]
medical, engineering, imaging, CT, microCT, animal, calibration, misalignment, geometric, detector, lag effect, artifact, correction, cone-beam, flat panel
Nationell ämneskategori
Medicinteknik
Identifikatorer
URN: urn:nbn:se:kth:diva-179873OAI: oai:DiVA.org:kth-179873DiVA, id: diva2:890787
Ämne / kurs
Medicinsk teknik
Utbildningsprogram
Teknologie masterexamen - Medicinsk teknik
Handledare
Examinatorer
Tillgänglig från: 2016-01-11 Skapad: 2016-01-04 Senast uppdaterad: 2022-06-23Bibliografiskt granskad

Open Access i DiVA

fulltext(22273 kB)697 nedladdningar
Filinformation
Filnamn FULLTEXT01.pdfFilstorlek 22273 kBChecksumma SHA-512
7f30ad6fe9515dca71fe0b2148d02cbf5e4ca4df97b69a45475e7622e49b9728b1bbd5c02f768fd35c4deb47b7edc40f57148872416460aff4d4e04125ef250a
Typ fulltextMimetyp application/pdf

Av organisationen
Skolan för teknik och hälsa (STH)
Medicinteknik

Sök vidare utanför DiVA

GoogleGoogle Scholar
Totalt: 697 nedladdningar
Antalet nedladdningar är summan av nedladdningar för alla fulltexter. Det kan inkludera t.ex tidigare versioner som nu inte längre är tillgängliga.

urn-nbn

Altmetricpoäng

urn-nbn
Totalt: 3778 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf