On Possibilities of Using Smart Meters for Emergency Grid Management: Analysing the Effect on Power Quality
KTH, Skolan för elektro- och systemteknik (EES), Elektroteknisk teori och konstruktion.ORCID-id: 0000-0003-4763-9429
2015 (Engelska)Ingår i: 2015 IEEE INNOVATIVE SMART GRID TECHNOLOGIES - ASIA (ISGT ASIA), 2015, artikel-id 7387158Konferensbidrag, Publicerat paper (Refereegranskat)
Abstract [en]

Electricity grids worldwide are continuing to be severely constrained and stretched to capacity. Certain grid conditions e.g., peak load crisis or loss of generation may lead to severe under frequency situations. Load shedding can then be useful to prevent the national grid from being overwhelmed. Typically, load shedding is done from medium voltage substation level and all customers including emergency service providers under that substation lose power. However, it is beneficial for a society to exclude emergency service providers from load shedding. Smart Meters (SMs) are generally equipped with remotely accessible switch which gives a unique opportunity to exclude prioritized customers during emergency load shedding. Distribution System Operators (DSOs) are currently using remote SM switching typically for one customer at a time. However, the SM switching technique has not been fully investigated with regard to multiple customers. In order to fulfill the gap, this paper presents results obtained from field tests on simultaneous multiple SMs switching with a main focus on the impact of multiple SMs switching on Power Quality (PQ). The results show that impact on PQ might be negligible for small number of SMs switching. Moreover, faster SMs switching and reliable communication system is found as an important prerequisite to use SMs for emergency load shedding.

Ort, förlag, år, upplaga, sidor
2015. artikel-id 7387158
Nyckelord [en]
Electrical Distribution System, Power Quality, Remote Switching, Smart Grid, Smart Meter
Nationell ämneskategori
Elektroteknik och elektronik
Identifikatorer
URN: urn:nbn:se:kth:diva-192053DOI: 10.1109/ISGT-Asia.2015.7387158ISI: 000380445100199Scopus ID: 2-s2.0-84964938411ISBN: 978-1-5090-1237-4 (tryckt)OAI: oai:DiVA.org:kth-192053DiVA, id: diva2:963017
Konferens
IEEE Innovative Smart Grid Technologies - Asia (ISGT ASIA 2015), NOV 03-06, 2015, Bangkok, THAILAND
Anmärkning

QC 20160907

Tillgänglig från: 2016-09-07 Skapad: 2016-09-05 Senast uppdaterad: 2016-09-07Bibliografiskt granskad

Open Access i DiVA

Fulltext saknas i DiVA

Övriga länkar

Förlagets fulltextScopus

Sök vidare i DiVA

Av författaren/redaktören
Bertling Tjernberg, Lina
Av organisationen
Elektroteknisk teori och konstruktion
Elektroteknik och elektronik

Sök vidare utanför DiVA

GoogleGoogle Scholar

doi
isbn
urn-nbn

Altmetricpoäng

doi
isbn
urn-nbn
Totalt: 212 träffar
RefereraExporteraLänk till posten
Permanent länk

Direktlänk
Referera
Referensformat
  • apa
  • harvard1
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annat format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annat språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf