Performance evaluation of passive containment cooling system of an advanced PWR using coupled RELAP5/GOTHIC simulation
KTH, Skolan för teknikvetenskap (SCI), Fysik, Kärnkraftssäkerhet.ORCID-id: 0000-0002-1179-2256
KTH, Skolan för teknikvetenskap (SCI), Fysik, Kärnkraftssäkerhet.
2016 (engelsk)Inngår i: NUCLEAR ENGINEERING AND DESIGN, ISSN 0029-5493, Vol. 310, s. 83-92Artikkel i tidsskrift (Fagfellevurdert) Published
Abstract [en]

Motivated to investigate the thermal hydraulic characteristics and performance of a passive containment cooling system (PCS) for a Generation III pressurized water reactor (PWR), a coupled RELAP5/GOTHIC model was developed, which was then employed to simultaneously simulate the transient responses of the PCS and the containment during a large break loss of coolant accident of the reactor. The results show that the PCS is capable of lowering the containment pressure to an acceptable level for a long period (up to 3 days). In a separate-effect study, it was found that the height of the PCS loop plays an important role in determining the flow characteristics and heat removal performance of the PCS. Within the range of the considered loop heights, phase change occurs in the riser of the loop after the height exceeds a specific value (between 13 m and 15 m), below which only single-phase flow takes place. With increasing height of the loop, the heat removal capability increases monotonically at first; however, it is no longer sensitive to the height after two-phase flow appears. Finally, a feed-and-bleed operation for the cooling tank of the PCS was proposed as an enhancement measure of the heat removal capacity, and the simulation results show it further mitigates the accident. Moreover, a simplified analytical model is developed to predict the impact of the feed-and-bleed flowrate on the PCS performance, which can be used in engineering design.

sted, utgiver, år, opplag, sider
Elsevier, 2016. Vol. 310, s. 83-92
HSV kategori
Identifikatorer
URN: urn:nbn:se:kth:diva-200214DOI: 10.1016/j.nucengdes.2016.10.004ISI: 000390736400008Scopus ID: 2-s2.0-84993967049OAI: oai:DiVA.org:kth-200214DiVA, id: diva2:1070758
Merknad

QC 20170202

Tilgjengelig fra: 2017-02-02 Laget: 2017-01-23 Sist oppdatert: 2017-02-02bibliografisk kontrollert

Open Access i DiVA

Fulltekst mangler i DiVA

Andre lenker

Forlagets fulltekstScopus

Personposter BETA

Huang, ZhengMa, Weimin

Søk i DiVA

Av forfatter/redaktør
Huang, ZhengMa, Weimin
Av organisasjonen

Søk utenfor DiVA

GoogleGoogle Scholar

doi
urn-nbn

Altmetric

doi
urn-nbn
Totalt: 29 treff
RefereraExporteraLink to record
Permanent link

Direct link
Referera
Referensformat
  • apa
  • ieee
  • modern-language-association-8th-edition
  • vancouver
  • Annet format
Fler format
Språk
  • de-DE
  • en-GB
  • en-US
  • fi-FI
  • nn-NO
  • nn-NB
  • sv-SE
  • Annet språk
Fler språk
Utmatningsformat
  • html
  • text
  • asciidoc
  • rtf